Main Features

range TeSys
Product name TeSys D Green
the type of device or its accessories Contactor
short name of the device LC1D
contactor application Electric motor control
Active load
Application category AC-1
AC-3
description of the poles 3P
configuration of the main contacts 3 N.O.
[Ue] rated operating voltage <= 690 V переменный ток 25...400 Hz для силовая цепь
[Icw] rated short-term permissible current 80 A (<= 60 °C) в <= 440 V AC-1 для силовая цепь
50 A (<= 60 °C) в <= 440 V AC-3 для силовая цепь
engine power, kW 22 kW at 380...400 V AC 50 Hz AC-3
25 kW at 415 V AC 50 Hz AC-3
30 kW at 440 V AC 50 Hz AC-3
30 kW at 500 V AC 50 Hz AC-3
33 kW at 660...690 V AC 50 Hz AC-3
15 kW at 220...230 V AC 50 Hz AC-3
engine power, hp 3 hp at 115 V AC 60 Hz for 1 phase motors
7.5 hp at 230/240 V AC 60 Hz for 1 phase motors
15 hp at 200/208 V AC 60 Hz for 3 phases motors
15 hp at 230/240 V AC 60 Hz for 3 phases motors
40 hp at 460/480 V AC 60 Hz for 3 phases motors
40 hp at 575/600 V AC 60 Hz for 3 phases motors
control circuit voltage 100...250 V DC
100...250 V lane Current 50/60 Hz
coil type AC/DC electronic
vspom. contacts available on each contactor 1 N.O. + 1 N.Z.
[Up] rated pulse withstand voltage 6 kV in accordance with IEC 60947
Overvoltage category III
[Ith] conditional thermal current in the open air 80 A in <= 60 °C для силовая цепь
10 A in <= 60 °C для цепь сигнализации
Rated switching capacity of Irms 900 A to 440 V for power circuit according to IEC 60947
140 A alternating current for alarm circuit according to IEC 60947-5-1
250 A direct current for alarm circuit according to IEC 60947-5-1
rated breaking capacity 900 A to 440 V for power circuit according to IEC 60947
[Icw] rated short-term sustained current 100 A 1 s alarm circuit
120 A 500 ms alarm circuit
140 A 100 ms alarm circuit
400 A <= 40 °C 10 с силовая цепь
810 A <= 40 °C 1 с силовая цепь
84 A <= 40 °C 10 мин силовая цепь
208 A <= 40 °C 1 мин силовая цепь
the corresponding fuse rating 100 A gG in <= 690 V координация тип 1 для силовая цепь
100 A gG in <= 690 V координация тип 2 для силовая цепь
10 A gG for alarm circuit according to IEC 60947-5-1
average total resistance 1.5mOhm V 50 Hz - Ith 80 A for power circuit
[Ui] rated insulation voltage 690 V for power circuit according to IEC 60947-4-1
690 V for alarm circuit according to IEC 60947-1
electrical wear resistance 1.8 Mcycles 42 A AC-3 at Ue <= 440 V
0.5 Mcycles 80 A AC-1 at Ue <= 440 V
power dissipated by one pole 3.7W AC-3
9.6W AC-1
protective cover With
mounting support Panel mounting
The rail
standards EN/IEC 60947-4-1
UL 60947-4-1
CSA C22.2 No 60947-4-1
EN/IEC 60947-5-1
certificationbr>CSA
CCC
EAC
KC
LROS (Lloyds register of shipping)
DNV-GL
accessions Control circuit : screw clamp 2 cable(s) 1...2.5 mm2 - cable stiffness: flexible - with cable tip
Power circuit : EverLink connectors with BTR screws 1 cable(s) 1...35 mm2 - cable stiffness: flexible - without cable tip
Power circuit : EverLink connectors with BTR screws 1 cable(s) 1...35 mm2 - cable stiffness: flexible - with cable tip
Power circuit : EverLink connectors with BTR 2 screws cable(s) 1...25 mm2 - cable stiffness: flexible - without cable tip
Power circuit : EverLink connectors with BTR 2 screws cable(s) 1...25 mm2 - cable stiffness: flexible - with cable tip
Control circuit : screw clamp 1 cable(s) 1...4 mm2 - cable stiffness: flexible - without cable tip
Control circuit : screw clamp 2 cable(s) 1...4 mm2 - cable stiffness: flexible - without cable tip
Control circuit : screw clamp 1 cable(s) 1...4 mm2 - cable stiffness: flexible - with cable tip
Control circuit : screw clamp 1 cable(s) 1...4 mm2 - cable stiffness: rigid cable
Control circuit : screw clamp 2 cable(s) 1...4 mm2 - cable stiffness: rigid cable
Power circuit : EverLink connectors with BTR screws 1 cable(s) 1...35 mm2 - cable stiffness: rigid cable
Power circuit : EverLink connectors with BTR screws 2 cable(s) 1...25 mm2 - cable stiffness: rigid cable
tightening torque Control circuit : 1.7 N-m - screw clamp - flat with a screwdriver. Ø 6 mm
Control circuit : 1.7 N-m - screw clamp - using a Philips No. 2 screwdriver
Power circuit : 8 N-m - EverLink connectors with screws BTR - cable 25...35 mm2 hexagon 4 mm
Power circuit : 5 Nm - EverLink connectors with BTR screws - 1...25 mm2 hex cable 4 mm
Response time 55...65 ms enable
20...120 ms opening (date code >=17221)
20...80 ms opening (date code >=18011)
a safe level of reliability B10d=1369863 cycles contactor with rated load according to EN/ISO 13849-1
B10d=20000000 cycles contactor with mechanical load according to EN/ISO 13849-1
mechanical wear resistance 6 million cycles
Operating frequency <= 3600 cyc/h at <= 60 °C

Additional features

the technology of using coils Built-in bidirectional peak limiting
voltage limits of the control circuit <= 0.1 Uc drop-out at 60 °C
0.85...1.1 Uc operational at 60 °C
power consumption when triggered 18 VA at 20 °C 50/60 Hz
starting power, W 14 W at 20 °C
power consumption during holding, V·A 1.8 VA at 20 °C 50/60 Hz
power consumption when holding, W 1.2 W at 20 °C
heat transfer 1.2 W at 50/60 Hz
the type of vspom. contacts Type mechanically coupled (1 N.O. + 1 N.Z.) in accordance with IEC 60947-5-1
Type duplicate contact (1 N.Z.) in accordance with IEC 60947-4-1
alarm circuit frequency 25...400 Hz
minimum switching current 5 mA for alarm circuit
minimum switching voltage 17 V for alarm circuit
time without overlap 1.5 ms when voltage is removed (between NC and NO contact)
1.5 ms when voltage is applied (between NC and NO contact)
insulation resistance > 10 mOhm for alarm circuit

Operating conditions

degree of IP protection IP20 front panel in accordance with IEC 60529
protective design TH in accordance with IEC 60068-2-30
degree of contamination 3
Ambient operating temperature -25...60 °C
ambient temperature during storage -60...80 °C
permissible air temperature around the device -40...70 °C at Uc
working height 3000 m without temperature degradation
Fire resistance 850 °C in accordance with IEC 60695-2-1
Fire resistance V1 in accordance with UL 94
mechanical resistance Vibration contactor is open 2 g (nom.), 5...300 Hz
Vibration contactor is closed 4 g (nom.), 5...300 Hz
Shocks The contactor is open 10 gn for 11 ms
Shocks The contactor is closed 15 g (nom.) for 11 ms
height 122 mm
width 55 mm
depth 120 mm
Product weight 0.997 kg
colour Grey SE GREY 6
Green SE GREEN 2