Main Features

product series Interface for discrete signals
the type of device or its accessories Interface module with electromechanical inputs
type of contacts 1 N.O.
[Uc] control circuit voltage 230...240 V
type of control circuit Per. current
control circuit current frequency 50/60 Hz
the size of the step in width 17.5 mm
[In] rated current <= 5.5 mA пер. ток
protection against switching on with reverse polarity Without
?????? ?? ????????? ????????? 16 A external fuse gF (Ik <= 2,5 кA пер. тока и Ik <= 100 A пост. тока)
16 A external fuse gG (Ik <= 2,5 кA пер. тока и Ik <= 100 A пост. тока)
[Ith] conditional thermal current in the open air 2 A in accordance with IEC 60947-1
local indication The green mechan. contact position indicator and 1 control signal status indicated by a green LED

Additional features

voltage limits of the control circuit 264 V Supply voltage threshold: 164 V
body color Gray
accessions Terminal block with screw terminals
release voltage <= 78 В
holding current >=1.5 mA trans. current
power dissipation, W <= 1.5 Вт
max. switching voltage 125 VDC
252 V alternating current
[Ue] rated operating voltage <= 125 V постоянный ток в соответствии с IEC 60947-5-1
<= 230 V переменный ток в соответствии с IEC 60947-5-1
network frequency 50/60 Hz
[Icw] rated short-term permissible current 1 A AC-13 Ue: 230 V for 1,000,000 cycles according to IEC 60947-5-1
1 A AC-14 Ue: 230 V for 1,000,000 cycles according to IEC 60947-5-1
1 A AC-15 Ue: 230 V for 1,000,000 cycles according to IEC 60947-5-1
1 A DC-13 Ue: 24 V for 1,000,000 cycles according to IEC 60947-5-1
2 A AC-12 Ue: 230 V for 1,000,000 cycles in accordance with IEC 60947-5-1
2 A DC-12 Ue: 24 V for 1,000,000 cycles in accordance with IEC 60947-5-1
minimum switching current 3 mA
minimum switching voltage 17 In
electrical reliability <= 0,00000001
Response time <= 12 мс между снятием напряжения с катушки и замыканием Н.З. контакта
<= 12 мс между снятием напряжения с катушки и замыканием Н.О. контакта
<= 12 мс между подачей напряжения на катушку и замыканием Н.З. контакта
<= 12 мс между подачей напряжения на катушку и замыканием Н.О. контакта
contact rattle time <= 3 мс
operating frequency, Hz <= 6 Гц при отсутствии нагрузки
<= 0.5 Гц при Ie
mechanical wear resistance >=20000000 cycles
[Ui] rated insulation voltage 250 V in accordance with IEC 60947-1
250 V according to VDE 0110 group C
Fire resistance V0 in accordance with UL 94
cable cross section 0.27...4 mm2, 1 hard wire
0.34...2.5 mm2, 1 or 2 flexible wires with cable tip
0.6...2.5 mm2, 1 or 2 flexible wires without a tip
0.27...2.5 mm2, 2-wire hard
working position Any position
installation category II in accordance with IEC 60947-1
mounting support Unbalanced DIN rail
Combined rail
Symmetrical DIN rail
Product weight 0.09 kg

Operating conditions

resistance to short-term loss of supply voltage 6 ms
electrical insulation strength 1500 V between independent contacts
2500 V between the connected interface and the ground
4000 V between coil and contact circuits
standards IEC 60947-5-1
Product certification BV
CSA
DNV
LROS (Lloyds register of shipping)
UL
degree of IP protection IP20 according to IEC 60529
protective design TC
Fire resistance 850 °C in accordance with IEC 60695-2-1
Impact resistance 50 gn for 11 ms in accordance with IEC 60068-2-27
vibration resistance 6 gn (f=10...55 Hz) in accordance with IEC 60068-2-6
electromagnetic compatibility Pulse surge resistance test 1.2/50 ms, 0.25 kV for U >50 V in accordance with IEC 255-4
Pulse surge resistance test 1.2/50 ms, 0.5 kV for U >50 V in accordance with IEC 255-4
Electrolytic discharge resistance test level 3.8 kV in accordance with IEC 61000-4-2
Test for resistance to switching interference, at the input/output of 1 kV in accordance with IEC 61000-4-4
Test for resistance to switching interference, in a 2 kV power supply circuit in accordance with IEC 61000-4-4
Ambient operating temperature -20...60 °C at Un
-5...40 °C unlimited use
ambient temperature during storage -40...70 °C
working height <= 3000 м
degree of contamination 3 in accordance with IEC 60947-5-1

Equipment warranty