Write to
WhatsApp
Write to
Telegram
Catalog

ABR1E112F Интерфейс ВХ 1НО 110-127В +светодиод

For comparison
To favorites
Vendor code:ABR1E112F
-100%
ABR1E112F Интерфейс ВХ 1НО 110-127В +светодиод
Brand
Pre-order
$0$0,01
11
Сопутствующие файлы
Delivery across Russia
On-line payment on the website
Discount system
Purchase returns
Description
Features
Reviews

Main Features

product series Interface for discrete signals
the type of device or its accessories Interface module with electromechanical inputs
type of contacts 1 N.O.
[Uc] control circuit voltage 110...127 V
type of control circuit Post. current
the size of the step in width 17.5 mm
[In] rated current <= 15 mA пост. ток
protection against switching on with reverse polarity With
?????? ?? ????????? ????????? 16 A external fuse gF (Ik <= 2,5 кA пер. тока и Ik <= 100 A пост. тока)
16 A external fuse gG (Ik <= 2,5 кA пер. тока и Ik <= 100 A пост. тока)
[Ith] conditional thermal current in the open air 2 A in accordance with IEC 60947-1
local indication The green mechan. contact position indicator and 1 control signal status indicated by a green LED

Additional features

voltage limits of the control circuit 140 V Supply voltage threshold: 75 V
body color Gray
accessions Terminal block with screw terminals
release voltage <= 16 В
holding current >=1.5 mA post. current
power dissipation, W <= 1.5 Вт
max. switching voltage 125 VDC
252 V alternating current
[Ue] rated operating voltage <= 125 V постоянный ток в соответствии с IEC 60947-5-1
<= 230 V переменный ток в соответствии с IEC 60947-5-1
network frequency 50/60 Hz
[Icw] rated short-term permissible current 1 A AC-13 Ue: 230 V for 1,000,000 cycles according to IEC 60947-5-1
1 A AC-14 Ue: 230 V for 1,000,000 cycles according to IEC 60947-5-1
1 A AC-15 Ue: 230 V for 1,000,000 cycles according to IEC 60947-5-1
1 A DC-13 Ue: 24 V for 1,000,000 cycles according to IEC 60947-5-1
2 A AC-12 Ue: 230 V for 1,000,000 cycles in accordance with IEC 60947-5-1
2 A DC-12 Ue: 24 V for 1,000,000 cycles in accordance with IEC 60947-5-1
minimum switching current 3 mA
minimum switching voltage 17 In
electrical reliability <= 0,00000001
Response time <= 12 мс между снятием напряжения с катушки и замыканием Н.З. контакта
<= 12 мс между снятием напряжения с катушки и замыканием Н.О. контакта
<= 12 мс между подачей напряжения на катушку и замыканием Н.З. контакта
<= 12 мс между подачей напряжения на катушку и замыканием Н.О. контакта
contact rattle time <= 3 мс
operating frequency, Hz <= 6 Гц при отсутствии нагрузки
<= 0.5 Гц при Ie
mechanical wear resistance >=20000000 cycles
[Ui] rated insulation voltage 250 V in accordance with IEC 60947-1
250 V according to VDE 0110 group C
Fire resistance V0 in accordance with UL 94
cable cross section 0.27...4 mm2, 1 hard wire
0.34...2.5 mm2, 1 or 2 flexible wires with cable tip
0.6...2.5 mm2, 1 or 2 flexible wires without a tip
0.27...2.5 mm2, 2-wire hard
working position Any position
installation category II in accordance with IEC 60947-1
mounting support Unbalanced DIN rail
Combined rail
Symmetrical DIN rail
Product weight 0.095 kg

Operating conditions

resistance to short-term loss of supply voltage 10 ms
electrical insulation strength 1500 V between independent contacts
2500 V between the connected interface and the ground
4000 V between coil and contact circuits
standards IEC 60947-5-1
Product certification BV
CSA
DNV
LROS (Lloyds register of shipping)
UL
degree of IP protection IP20 according to IEC 60529
protective design TC
Fire resistance 850 °C in accordance with IEC 60695-2-1
Impact resistance 50 gn for 11 ms in accordance with IEC 60068-2-27
vibration resistance 6 gn (f=10...55 Hz) in accordance with IEC 60068-2-6
electromagnetic compatibility Pulse surge resistance test 1.2/50 ms, 0.25 kV for U >50 V in accordance with IEC 255-4
Pulse surge resistance test 1.2/50 ms, 0.5 kV for U >50 V in accordance with IEC 255-4
Electrolytic discharge resistance test level 3.8 kV in accordance with IEC 61000-4-2
Test for resistance to switching interference, at the input/output of 1 kV in accordance with IEC 61000-4-4
Test for resistance to switching interference, in a 2 kV power supply circuit in accordance with IEC 61000-4-4
Ambient operating temperature -20...60 °C at Un
-5...40 °C unlimited use
ambient temperature during storage -40...70 °C
working height <= 3000 м
degree of contamination 3 in accordance with IEC 60947-5-1

Equipment warranty

Period The warranty period for this equipment is 18 months from the date of its commissioning, which is confirmed by the relevant document, but not more than 24 months from the date of delivery
Features
Brand
No reviews yet — yours could be the first.
All reviews 0
overall rating
Список отзывов пуст