CERABAR PMP55 Pressure transmitter PMP55 AA12QA1MGBT7JE4A
Pressure converter Cerabar PMP55 With a metal separating diaphragm, it is used in any industry to measure pressure, level, volume and mass in liquids. It is suitable for applications at high pressure, as well as at extreme process temperatures from -70 to +400°C.The quick setup menu with adjustable measuring range provides easy commissioning, reduces costs and saves time. SIL2 in accordance with IEC 61508 (GOST R IEC 61508) and IEC 61511 (GOST R IEC 61511)
Specifications:
Principle of measurement Absolute and overpressure Characteristics/Application An intelligent pressure transducer with a strain-resistant measuring cell and a welded metal diaphragm with a seal.
Food /Communication 4 ..20mA HART:
11,5...45В DC
Ex ia: 11,5...30В DC
PROFIBUS PA
FOUNDATION Fieldbus
The error is 0,15%
Platinum 0.075 calibration%
Long-term stability 0.1% of the upper limit of the range per year
The ambient temperature is 40°C...85°C
The operating temperature is 70°C...400°C
Operating pressure abs. /max. overpressure limit 600bar
The pressure measuring range is 1bar...400bar
Wetted parts 316L
AlloyC
Montel
Tantalum
Rhodium
Process connection Separation diaphragm
Flanged (DIN, ANSI, JIS)
Tri-Clamp ISO2852
Hygienic
Max. Measurement value 4000m H2O
Exit 4...20 mA HART
PROFIBUS PA
FOUNDATION Fieldbus
Certificates/Technical standards
CSA
FM
IECEx
TIIS
IS BORN
SIL
3A/EHEDG
inspection certificates
Safety approvalsSIL
Design Certificate EN 10204-3.1
NACE MR0175, MR0103
AD2000
Hygiene certifications3a, EHEDG
CoC ASME-BPE
Marine Certificate GL/ABS/LR/BV/DNV
Optional display
Application range Measuring cell: Metal welded