Electrical Conductivity Sensor CLS54D-11H3/0 Indumax CLS54D CLS54D-AAMV5A3A+F4
Indumax CLS54D Electrical Conductivity Sensor
Toroidal conductivity sensor based on Memosens technology for hygienic and sterile environments
The Indumax CLS54D inductive conductivity sensor is designed to protect all products and processes in accordance with the strictest hygiene and sterility requirements. Its outstanding performance and unique hygienic design ensure the highest quality of products and safety. Thanks to Memosens technology, the CLS54D combines maximum process and data integrity with ease of operation. It is resistant to corrosion and moisture, allows laboratory calibration and simplifies preventive maintenance.
Advantages
- Unique hygienic design, eliminating the risk of contamination
- Accessibility of all process connections widely used in areas with high hygiene requirements and conforming to the standards of EG 2023/2006 and 1935/2004
- The housing is made of food grade PEEK without joints and grooves
- Certified biocompatibility according to USP Class VI
- The possibility of non-selective cleaning (CIP) and non-selective sterilization (SIP)
- Convenient maintenance planning with Memobase Plus for easy data and sensor management
- Measurement reliability due to active connection monitoring and EMC protection
Scope of application
- Indumax CLS54D is a toroidal conductivity sensor for use in hygienic and sterile processes in the food and pharmaceutical industries, for example:
- Phase separation in product/water and product/product mixtures in the pipeline
- Control of the CIP (non-selective cleaning) process in the return channel
- Concentration control during replenishment of reagents for CIP purification
- Monitoring of the product in the pipeline, during bottling, during quality control
- Leak control
- Unique hygienic design, EHEDG and 3-A certified.
The principle of measurement
Inductive sensors
Application
Food and pharmaceutical industries, as well as biotechnology.
Specifications
- It is specially designed for use in applications requiring compliance with sanitary and hygienic standards, in particular for the following applications:
- Phase separation, CIP flushing control, concentration control, product monitoring, leak detection.
The measurement range is 100 microns/cm...2000 mSm/cm Cell constant k: 6.3 1/cm
The principle of measurement
Inductive conductivity measurement
Construction
Hygienic design with a PEEK housing for the food industry without seams and cracks, confirmed by hygienic certificates.
Material
- Materials in contact with the product: Primary PEEK
- Surface roughness: Ra < 0,8 мкм
Operating temperature
- -10°C...125°C
- (14°F...257°F)
Стерилизация: 150°C/6 бар (макс. 60 мин) (302°F/87 psi абс до 60 мин)
Operating pressure
- 13 bar abs up to 90°C (188.5 psi abs up to 194°F)
- 9 bar at 125°C (130.5 psi abs at 257°F)
Temperature sensor
Pt 1000 (Class A) with temperature response time T90 < 27 с.
Connection: Milk pipe, aseptic fitting, ISO 2852 clamp, SMS-2", Varivent N DN 40-125, Neumo Biocontrol D50.
Degree of protection IP68/NEMA6P
Additional certificates of FDA, EHEDG, 3-A, Biological reactivity (USP, Class VI, Parts 87 and 88).