MX21-2LD92/0 Waterpilot FMX21 Level Sensor
Waterpilot FMX21 Hydrostatic Level Sensor
The Waterpilot FMX21 transmitter with a capacitive, oil-free ceramic measuring cell is typically used in environmental processes and applications to measure the hydrostatic level. With the HART output, the measurement ranges can be freely adjusted, and the density level can be measured with density compensation. It is certified for drinking water and offers integrated temperature measurement. Versions are also available for use in wastewater and sludge or for use in salt water.
Benefits
- Durable overload-resistant ceramic sensor of high purity (99.9% Al 2 O 3 )
- Flexible scaling from 4 to 20 mA with superimposed HART 6.0 output
- The highest level of accuracy using density correction with temperature compensation
- Simultaneous measurement of level and temperature using the built-in Pt100 temperature sensor
- A wide range of accessories provides complete solutions for measuring points
- A climatically tested sensor thanks to fully sealed electronics and a two-component pressure compensation system
- Small outer diameter of 22 mm (0.87 in), suitable for use in drinking water and for use in wells and boreholes with small diameters
Scope of application
Three different options for drinking water, wastewater and wastewater, salt water.
- Process connections: Suspension clamp, cable gland
- Temperature: from -10 to + 70 aposematic (from 14 to 158 aposematic)
- Measuring range: 0 to 20 bar /200 m H 2 0 (0 to 300 psi /600 ft H 2 O)
- Accuracy: ± 0.2%, "platinum" ± 0.1%
- International explosion protection certificates, marine certificates, drinking water approval
Features and Specifications
The principle of measurement |
hydrostatic |
Characteristic /Application |
Compact probe with ceramic cell for hydrostatic level measurement, |
Specialties |
Automatic density compensation |
Delivery /Communication |
10,5 ... 35 V DC |
accuracy |
0,2% |
Long-term stability |
0.1% URL /year |
Ambient temperature |
From -10 ° C ... 70 ° C |
Process temperature |
From -10 ° C ... 70 ° C |
Pressure measurement range |
100 mbar ... 20 bar |
Main wetted parts |
22mm and 42mm Diameter: Seal, 316L, Ceramic |
Joining the process |
Hanging clamp |
Maximum. Measuring distance |
200 m H2O |
connection |
4 ... 20 mA |
Certificates /Permissions |
ATEX, FM, CSA, CSA C /US, IEC Ex, NEPSI |
Approval of marine vessels |
GL /ABS /BV /DNV |
Drinking water permits |
KTW /NSF /ACS |
Options |
Absolute measuring cell |
Limits of application |
Measuring cell: ceramic |