Write to
WhatsApp
Catalog

HMIGTO5315 Сенс.цвет.терм.10,4"640×480 TFT,RJ45 RS232/485,SUB-D,1Ethernet TCP/IP,96Mб/512кБ

For comparison
To favorites
Vendor code:HMIGTO5315
-100%
HMIGTO5315 Сенс.цвет.терм.10,4"640×480 TFT,RJ45 RS232/485,SUB-D,1Ethernet TCP/IP,96Mб/512кБ
Brand
Pre-order
$0$0.01
11
Related files
Delivery across Russia
On-line payment on the website
Discount system
Purchase returns
Description
Features
Reviews

Main Features

range TeSys
Product name TeSys B
the type of device or its accessories Contactor
short name of the device LC1BM
contactor application Engine-heating-lighting
Application category AC-1
AC-3
type of control circuit Per. current
coil type Standard
description of the poles 3P
configuration of the main contacts 3 N.O.
[Icw] rated short-term permissible current 1000 A (<= 55 °C) переменный ток AC-3 для силовая цепь
1250 A (<= 40 °C) переменный ток AC-1 для силовая цепь
engine power, kW 530 kW at 1000 V AC 50/60 Hz AC-3
160 kW at 400 V AC 50/60 Hz AC-4
280 kW at 220...230 V AC 50/60 Hz AC-3
500 kW at 380...400 V AC 50/60 Hz AC-3
530 kW at 415 V AC 50/60 Hz AC-3
560 kW at 440 V AC 50/60 Hz AC-3
600 kW at 500 V AC 50/60 Hz AC-3
670 kW at 660...690 V AC 50/60 Hz AC-3
vspom. contacts available on each contactor 2 N.O. + 2 N.Z.
control circuit voltage 220 V lane The current is 50...400 Hz

Additional features

voltage limits of the control circuit 0.3...0.5 Uc release 50...400 Hz
0.85...1.1 Uc is in operation state 50...400 Hz
[Ui] rated insulation voltage 1000 V - for power circuit - conforming to IEC 60158-1
1000 V - for power circuit - conforming to IEC 60947-4
1500 V - - power circuit - corresponding to VDE 0110 group C
switch design Stationary
mounting support Tire support bracket
Perforated mounting rails
tightening torque Power circuit : 35 N-M - tires
[Ue] rated operating voltage <= 1000 V переменный ток 50/60 Гц для силовая цепь
[Ith] conditional thermal current in the open air 1250 A V <= 40 °C для силовая цепь
Rated switching capacity of Irms 10000 A to 1000 V alternating current for power circuit according to IEC 60158-1
10000 A to 1000 V alternating current for power circuit according to IEC 60947-4
rated breaking capacity 10000 A to 440 V for power circuit according to IEC 60158-1
10000 A to 440 V for power circuit according to IEC 60947-4
4000 A to 1000 V for a power circuit according to IEC 60158-1
4000 A to 1000 V for a power circuit according to IEC 60947-4
8000 And 660...690 V for power circuit according to IEC 60158-1
8000 And 660...690 V for power circuit according to IEC 60947-4
9000 A to 500 V for power circuit according to IEC 60158-1
9000 A to 500 V for power circuit according to IEC 60947-4
the corresponding fuse rating 1200 A aM V <= 440 V для силовая цепь
1200 A gI in <= 440 V для силовая цепь
1500 A gI in <= 440 V для силовая цепь
average total resistance 0.18mOhm V 50 Hz - Ith 1250 A for power circuit
power dissipated by one pole 180 W AC-3 - Ith 1250 A
280 W AC-1 - Ith 1250 A
power consumption when triggered 1300 VA
power consumption during holding, V·A 31 VA 50/60 Hz
Response time 100...150 ms switching on
50...100 ms shutdown
mechanical wear resistance 1200000 cycles
Operating frequency 120 cycle/h at <= 55 °C
height 490 mm
width 570 mm
depth 475 mm
Product weight 57 kg

Operating conditions

standards BS 5424
IEC 60158-1
IEC 60947-4
NF C 63-110
VDE 0660
Product certification BV
CSA
RINA
protective design TC
TH
Ambient operating temperature -5...55 °C
ambient temperature during storage -60...80 °C
working height 3000 m without temperature degradation

Features
Brand
No reviews yet — yours could be the first.
All reviews 0
overall rating
Список отзывов пуст