Description
Features
Reviews
TRIO POWER power supplies with a standard set of functions
The TRIO POWER series power supplies with push-in clamp are ideal for applications in mechanical engineering. All functions and compact design of single- and three-phase modules optimally meet high requirements. Reliable power supply of consuming devices in difficult operating conditions is provided by power supplies of extremely robust electrical and mechanical design.
Environmental conditions
Degree of protection | IP20 |
---|---|
Flammability class according to UL 94 (enclosures/terminals) | V0 |
Ambient temperature (during operation) | -25 °C ... 70 °C (>60 °C изменение хар-к: 2,5 %/K) |
Ambient temperature (tested by startup type) | -25 °C |
Ambient temperature (storage/transport) | -40 °C ... 85 °C |
Max. permissible rel. air humidity (during operation) | ≤ 95% (At 25 °C, without condensation) |
Climate class | 3K3 (complies with EN 60721) |
Degree of contamination | 2 |
Installation height | ≤ 5000 м (>2000 м, изменение хар-к: 10 %/1000 м) |
Input data
The range of nominal input voltages | 3x 400 V AC ... 500 V AC |
---|---|
2x 400 V AC ... 500 V AC | |
Input voltage range | 3x 400 AC... 500 AND -20 % ....+15 % |
2x 400 AC... 500 AND -10 % ... +15 % | |
AC frequency range | 50 Hz ... 60 Hz |
Leakage current on PE | < 0,25 мА |
Current consumption | 3x 0.4A (400 V AC) |
3x 0.3A (500 V AC) | |
2x 0.6A (400 V AC) | |
2x 0.5A (500 V AC) | |
Rated power consumption | 243.6 VA |
Inrush current pulse | ≤ 22 A (standard (typical)) |
Battery life | type. 20 ms (400 V AC) |
type. 20 ms (500 V AC) | |
Input fuse | 3.15 A (internal (module protection), Inert type) |
Selecting the appropriate fuse for input protection | 6 A ... 16 A (Characteristic B, C, D, K) |
Power factor (cos phi) | 0,55 |
Name of the protection | Surge protection during transients |
Protective circuit /module | Varistor |
Features
Brand
Phoenix
No reviews yet — yours could be the first.
All reviews 0
Список отзывов пуст