Electronic soft-start devices SIRIUS 3RW40 designed for smooth start and stop of three-phase asynchronous motors. This Siemens product line provides built-in additional functions, such as: adjustable current limitation, overload protection of the motor, self-protection of the device, as well as thermistor protection of the motor.
The main applications of soft starters are screw compressors, fans, mixers, escalators, lathes and milling machines and many other industrial sectors. Our organization has demonstrated a clear example of the use of SIRIUS 3RW40 soft starters in industrial enterprises where fan equipment is used.
In most cases, fan equipment is characterized by very high inertia values, leading to long starts. At the same time, during direct start, the motors are exposed to shock currents for a long time, and significant mechanical forces are transmitted to the motor shaft. This leads to overheating of the windings and rapid wear of the bearings, as well as belt drives are used in this type of equipment, which, during direct start-up, increase the likelihood of slipping and rupture of the belts.
The use of SIRIUS RW40 soft starters by our specialists has made it possible to eliminate, or at least significantly reduce, a number of problems associated with this in many industrial enterprises and factories.
Technical specifications of Sirius 3RW40
Parameters | Values |
Rated current, A | 12,5-432 |
Rated voltage, V | 200-600 |
The power of the connected electric motor, W | 5,5-250 |
Control voltage, V | Габариты от S0 до S3: 24 V AC/DC или 110-230 V AC/DC Dimensions from S6 to S12: 115 V AC or 230 V AC
|
Permissible temperature, °C | During operation: -25...+60 During storage: -40...+80 |
Degree of protection | IP 20 |
Description of the codes for the order
Registered number |
Nomina- linen current, A |
Powerful- ness, kW | |||
Screw clamps | Spring-loaded clamps | With a thermistor engine protection | |||
Screw clamps | Spring-loaded clamps | ||||
3RW4024-1BB14 | 3RW4024-2BB14 | 3RW4024-1TB04 | 3RW4024-2TB04 | 12,5 | 5,5 |
3RW4026-1BB14 | 3RW4026-2BB14 | 3RW4026-1TB04 | 3RW4026-2TB04 | 25 | 11 |
3RW4027-1BB14 | 3RW4027-2BB14 | 3RW4027-1TB04 | 3RW4027-2TB04 | 32 | 15 |
3RW4028-1BB14 | 3RW4028-2BB14 | 3RW4028-1TB04 | 3RW4028-2TB04 | 38 | 18,5 |
3RW4036-1BB14 | 3RW4036-2BB14 | 3RW4036-1TB04 | 3RW4036-2TB04 | 45 | 22 |
3RW4037-1BB14 | 3RW4037-2BB14 | 3RW4037-1TB04 | 3RW4037-2TB04 | 63 | 30 |
3RW4038-1BB14 | 3RW4038-2BB14 | 3RW4038-1TB04 | 3RW4038-2TB04 | 72 | 37 |
3RW4046-1BB14 | 3RW4046-2BB14 | 3RW4046-1TB04 | 3RW4046-2TB04 | 80 | 45 |
3RW4047-1BB14 | 3RW4047-2BB14 | 3RW4047-1TB04 | 3RW4047-2TB04 | 106 | 55 |
3RW4055-6BB44 | 3RW4055-2BB44 | - | 134 | 75 | |
3RW4056-6BB44 | 3RW4056-2BB44 | - | 230 | 132 | |
3RW4073-6BB44 | 3RW4073-2BB44 | - | 280 | 160 | |
3RW4074-6BB44 | 3RW4074-2BB44 | - | 356 | 200 | |
3RW4075-6BB44 | 3RW4075-2BB44 | - | 432 | 250 | |
3RW4076-6BB44 | 3RW4076-2BB44 | - | 432 | 315 |
Note: The order numbers are given for devices with a control voltage of 110-230 V AC/DC, for soft starters with a control voltage of 24 V AC/DC, the digit 1 in the penultimate position in the designation of the order number must be replaced by the digit 0. To select soft starters with thermistor motor protection with an operating voltage from 400 to 600 V, it is necessary change the number 4 in the last position in the designation of the registered number to the number 5.
For example: 3RW4024-1BB04 – UPP with a rated current of 12.5A, power of 5.5kW, with a control voltage of 24 V AC/DC.