Write to
WhatsApp
Catalog

Контактор реверсивный 4р(4НО) AC1 200A 220В 50Гц (LC2D115004M7)

For comparison
To favorites
Vendor code:LC2D115004M7
-100%
Контактор реверсивный 4р(4НО) AC1 200A 220В 50Гц (LC2D115004M7)
Brand
Pre-order
$0$14.93
11
Related files
Delivery across Russia
On-line payment on the website
Discount system
Purchase returns
Description
Features
Reviews

Main Features

range TeSys
Product name TeSys D
the type of device or its accessories Contactor switch
short name of the device LC2D
contactor application Active load
Application category AC-1
Product configuration Pre-assembled with a power reverse busbar
description of the poles 4P
configuration of the main contacts 4 N.O.
[Ue] rated operating voltage <= 460 В постоянный ток для силовая цепь
<= 1000 V переменный ток 25...400 Hz для силовая цепь
[Icw] rated short-term permissible current 200 A (<= 60 °C) в <= 440 V переменный ток AC-1 для силовая цепь
type of control circuit Per. Current 50/60 Hz
control circuit voltage 220 V lane Current 50/60 Hz
[Up] rated pulse withstand voltage 8 kV in accordance with IEC 60947
Overvoltage category III
[Ith] conditional thermal current in the open air 200 A V <= 60 °C для силовая цепь
Rated switching capacity of Irms 1260 A to 440 V for power circuit according to IEC 60947
rated breaking capacity 1100 A to 440 V for power circuit according to IEC 60947
[Icw] rated short-term sustained current 1100 A <= 40 °C 1 с силовая цепь
250 A <= 40 °C 10 мин силовая цепь
550 A <= 40 °C 1 мин силовая цепь
950 A <= 40 °C 10 с силовая цепь
the corresponding fuse rating 200 A gG in <= 690 V координация тип 2 для силовая цепь
250 A gG in <= 690 V координация тип 1 для силовая цепь
average total resistance 0.6mOhm V 50 Hz - Ith 200 A for power circuit
[Ui] rated insulation voltage 1000 V for power circuit according to IEC 60947-4-1
600 V for CSA certification power circuit
600 V for UL certification power circuit
electrical wear resistance 0.8 Mcycles 200 A AC-1 <= 440 V
power dissipated by one pole 24W AC-1
protective cover With
type of blocking Mechanical
mounting support Panel mounting
The rail
standards CSA C22.2 № 14
EN 60947-4-1
EN 60947-5-1
IEC 60947-4-1
IEC 60947-5-1
UL 508
certificationbr>CSA
CCC
EAC
GL
BV
DNV
RINA
accessions Control circuit : screw clamp 2 cable(s) 1...2.5 mm2 - cable stiffness: flexible - without cable tip
Control circuit : screw clamp 2 cable(s) 1...2.5 mm2 - cable stiffness: flexible - with cable tip
Control circuit : screw clamp 2 cable(s) 1...2.5 mm2 - cable stiffness: rigid cable - without cable tip
Control circuit : screw clamp 1 cable(s) 1...2.5 mm2 - cable stiffness: flexible - with cable tip
Control circuit : screw clamp 1 cable(s) 1...2.5 mm2 - cable stiffness: flexible - without cable tip
Control circuit : screw clamp 1 cable(s) 1...2.5 mm2 - cable stiffness: rigid cable - without cable tip
Power circuit : connector 1 cable(s) 10...120 mm2 - cable stiffness: flexible - without cable tip
Power circuit : Connector 2 cable(s) 10...50 mm2 - cable stiffness: flexible - without cable tip
Power circuit : connector 1 cable(s) 10...120 mm2 - cable stiffness: flexible - with cable tip
Power circuit : Connector 2 cable(s) 10...50 mm2 - Cable stiffness: flexible - with cable tip
Power circuit : connector 1 cable(s) 10...120 mm2 - cable stiffness: rigid cable - without cable tip
Power circuit : Connector 2 cable(s) 10...50 mm2 - cable stiffness: rigid cable - without cable tip
tightening torque Control circuit : 1.2 N-m - screw clamp - flat with a screwdriver. Ø 6 mm
Control circuit : 1.2 N-m - screw clamp - using a Philips No. 2 screwdriver
Power circuit : 12 N-M - 4 mm hex socket
Response time 6...20 ms shutdown
20...50 ms switching on
a safe level of reliability B10d=1369863 cycles contactor with rated load according to EN/ISO 13849-1
B10d=20000000 cycles contactor with mechanical load according to EN/ISO 13849-1
mechanical wear resistance 8000000 cycles
Operating frequency 2400 cycle/h in <= 60 °C

Additional features

the technology of using coils Built-in symmetrical protective zener diode
voltage limits of the control circuit 0.3...0.5 Uc release at 55 °C, alternating current 50/60 Hz
0.8...1.15 Uc is in operation at 55 °C, alternating current 50/60 Hz
power consumption when triggered 280...350 V·A at 20 °C (cos ϕ 0.8) 60 Hz
280...350 V·A at 20 °C (cos ϕ 0.8) 50 Hz
power consumption during holding, V·A 2...18 V·A at 20 °C (cos ϕ 0.3) 60 Hz
2...18 V·A at 20 °C (cos ϕ 0.3) 50 Hz
heat transfer 3...8 Watts at 50/60 Hz

Operating conditions

degree of IP protection IP20 front panel in accordance with IEC 60529
protective design TH in accordance with IEC 60068-2-30
degree of contamination 3
Ambient operating temperature -5...60 °C
ambient temperature during storage -60...80 °C
permissible air temperature around the device -40...70 °C at Uc
working height 3000 m without temperature degradation
Fire resistance 850 °C in accordance with IEC 60695-2-1
Fire resistance V1 in accordance with UL 94
mechanical resistance Vibration contactor is open 2 g (nom.), 5...300 Hz
Vibration contactor is closed 4 g (nom.), 5...300 Hz
Shocks The contactor is closed 15 g (nom.) for 11 ms
Shocks The contactor is open 6 g (nom.) for 11 ms
height 158 mm
width 334 mm
depth 148 mm
Product weight 7.4 kg

Features
Brand
No reviews yet — yours could be the first.
All reviews 0
overall rating
Список отзывов пуст