Power Flex Cable Conductix-Wampfler HVR /HVR-D It has a large margin of safety and is designed to work with medium and high dynamic loads in the winding mode on cable drums, copes well with mechanical stress during continuous operation. It is a popular solution for working with motorized coils, as well as for connecting and powering various lifting devices, such as container and port cranes, mining equipment, stacker reclaimers.

The cable structure has excellent elasticity, protection from the effect of torsion due to special rubber and built-in reinforcing braid, high resistance to wear. It is suitable for outdoor and indoor work, as it has a wide temperature range (up to -30 °C, expansion to 45 °C on request) and is not whimsical to ultraviolet radiation. It does not contain silicone and chlorofluorocarbons.

Version FO It has built-in fiber-optic channels for data transmission, with up to 24 fibers.

Technical Characteristics of the Conductix-Wampfler HVR /HVR-D cable:

  • Number of conductive cores: 3;
  • Section of the vein: 25 - 150 mm2;
  • Diameter: 41.0 - 58.0 mm;
  • Rated voltage: 3.6-6 kV /6 - 10 kV /8.7-15 kV /12-20 KV;
  • Conductor: electrolytic copper, thin-wire;
  • Configuration: flexible Class 5 (IEC 60228);
  • Marking of veins: numbered in black and white or vice versa, the ground wire is divided into 3 elements or in half if there is an optical fiber;
  • Isolation: 3 layers crosslinked: the inner layer is semiconductor, ethylene propylene rubber (EPR), the outer layer is semiconductor insulation;
  • The inner shell: GM1b synthetic rubber;
  • The outer shell: chlorinated rubber compound 5GM5, red color;
  • Maximum operating speed (m/min): 180;
  • Maximum tension (N/mm?): 20;
  • Minimum bending radius: 12 x Cable diameter (winding), 15 x Cable diameter (pulley), 20 x Cable diameter (with S-type guide);
  • The maximum permissible temperature for the conductor: +90 °C;
  • The temperature is stationary: -50 °C ... +80 °C;
  • Temperature is movable: -30 °C ... +80 °C;

Standard sizes: (N)TSCGEWOEU /(N)TSCGEWOEU-FO.

Environmental requirements: Outdoor and indoor use, resistant to UV radiation, ozone, oils, moisture, flame retardant.