Low voltage power and control cables Conductix-Wampfler RXG /RXG-D they have a flexible elastic structure, high tensile strength and wear resistance, are designed for working in harsh conditions, with high mechanical loads and high displacement dynamics. Horizontal and vertical use, an excellent choice for motorized coils, operated with lifting and transporting equipment, such as port crane installations.
The composite modification of the RXG-D has data transmission channels, including optical fiber.
It is used outdoors, wide temperature range (especially frost-resistant versions on request), immune to moisture, ultraviolet and ozone. It does not contain silicone.
Technical Characteristics of the Conductix-Wampfler RXG /RXG-D cable:
- Number of conductive conductors: 3 - 56;
- Section of the vein: 1.5 - 240 mm2;
- Core diameter: 13.0 - 70.0 mm;
- Rated voltage: 0.6 - 1 kV;
- Conductor: electrolytic copper;
- Configuration: particularly flexible Class 5 or FS (IEC 60228);
- Marking of veins: in accordance with DIN VDE 0293 part 308, over 6-and numbered in black and white or vice versa, green-yellow ground wire;
- Twisting of veins: layered, short laying length;
- Isolation: based on ethylene propylene rubber (EPR);
- The inner shell: Polychloroprene (PCP);
- Protective layer: braiding against the effect of twisting;
- The outer shell: Polychloroprene (PCP), yellow;
- Maximum operating speed (m/min): 240 (horizontal), 120 (vertical, over on request);
- Maximum tension (N/mm2): 30;
- Minimum bending radius: 6 x Cable diameter (winding), 7.5 x Cable diameter (with guide);
- The maximum permissible temperature for the conductor: +90 °C;
- The temperature is stationary: -50 °C ... +80 °C;
- Temperature is movable: -35 °C ... +80 °C;
Standard sizes: (N)SHTOEU-J.
Environmental requirements: outdoor and indoor use, resistant to UV radiation, ozone, oils, moisture, low flammability (IEC 60332-1), short-term use in water is acceptable when submerged up to 50 meters.