Main application areas
- Water
- Water intake
- Water treatment
- Mining
- Wells, mines
- Lake water, water lifting dam
- Sprinkling irrigation, irrigation
- Maintaining the groundwater level
- Industry and technological process
- Process
- Water transportation
- Public power plants
- Energy industry
Single–stage or multi-stage centrifugal pumps of sectional type; single-flow, for vertical installation and - depending on the number of stages – horizontal installation. Radial or mixed flow parts with reduced impeller diameters, driven by submersible electric motors.
Scope of application: for pumping clean or slightly polluted water in the general water supply, sprinkling and watering, lowering or maintaining the groundwater level, increasing pressure, for emergency water supply, in mining and fountain installations, etc. The suction housing is installed between the pump and the motor, equipped with a filter to protect the pump from ingress of coarse particles contained in the liquid. Permissible sand content in the liquid: 50 g/m#. Optionally with a check valve or a connecting pipe.
Types of orders:
S 100D, UPA 100C, UPA 150C, UPA 200, UPA 200B, UPA 250C, UPA 300, UPA 350, UPZ, BSX - BSF.
Overview of technical data
Q (50Hz) | 22.0 – 1010.0 (m³/h) |
H (50Hz) | 15.0 – 480.0 (m) |
Type of bearing | slide underpin |
Hole Diameter (inch) | 14, 08, 10, 12, 06 |
Separation of the body | transverse (radial) |
Type of impeller material (according to the standard | GJS-400, CUAL10FE5NI5, PPO GF30, CUSN10, GJL-200 |
Drive | electric motor |
Drive motor frequency | 50 Hz /60 Hz |
Type of drive | electric motor |
Drive motor voltage | low voltage, high voltage |
Electrical connector | < 6,6 kВ, 3~ |
1. type of impeller | radial/diagonal |
Number of impeller inputs | single-threaded |
Other types of impeller | radial/diagonal |
Impeller material (according to E standard | CUSN10, CC480K, PPO GF30 |
Type of coupling | directly |
Type of lubricant | lubrication of the pumped medium |
Pressure housing material (according to the standard | JL 1040, JL 1030, CC480K, JS 1030 |
Max. permissible liquid temperature | 50 (°C) |
Maximum operating pressure | PN64 |
Installation of the unit | "wet" installation |
Shaft material (according to EN standard) | 1.4462, 1.4021 |
The material of the stage body (according to the E standard | JS 1030, JL1030, CC333G, JL 1040, CC480K, GJL-200, CUSN10, CUAL10FE5NI5, GJS-400 |
The material of the suction body (according to the standard | GJS-400, GJL-200, CUAL10FE5NI5, CUSN10, JS 1030, JL1030, CC480K |
Suction characteristics | non-self-priming |
Acceptable for drinking water | yes |
Type of connection | thread, flange |
Type of stage housing | stage body with guide device |
Type of suction housing | housing with an annular camera |
UNSPSC classification | 4015150300 |
Housing material (according to EN standard) | GJL-200, JS1030, JL 1030, 1.4593, CUAL10FE5NI5, CC480K, 1.4408, CUSN 10, GJS-400, CC333G, JL1030 |
eClass | 36410000, 00000000, 36410106, 36410100 |
Installation position | horizontal or vertical |
Type of shaft seal | mechanical seal, shaft O-ring |
Housing material | cast iron with spherical graphite, bronze |
Max. working pressure from the pressure sides | 57 (bar) |
Max. drive power | 380 (kW) |
Type of installation | stationary |
Max. rotation speed | 3500 (1/min) |