During the operation of the drive technology, which uses semiconductor elements, parasitic high-frequency harmonics are produced, which have a negative impact on the power supply network, as a result of which the shape of the sinusoidal voltage is distorted. The electromagnetic interference that occurs in this case negatively affects the operation of other machines and equipment, unforeseen failures and stops occur, products are damaged, and the continuity of the technological process is disrupted.

In addition, high-frequency distortions are the causes of power losses in all electric machines and devices powered from the mains.

To limit the propagation of high-frequency harmonics at the input of electric drives and thyristor modules, it is recommended to use network chokes and reactors.

The installation of inductive elements also allows to extinguish switching overvoltages, in case of a short circuit, the value of the steady-state short-circuit current and its rate of increase are reduced.    Network reactors protect low-power electronic devices from the effects created by welding equipment, thyristor regulators, DC drives.

Chokes and reactors in drive technology act as a two-way buffer between the electric drive and the power supply network, reducing harmful mutual effects.

When carrying out repair and modernization projects, our engineers actively use network chokes and reactors in the power supply circuits of Leroy Somer electric drives, Control Techniques series Mentor MPUnidrive SPDigidrive SKCommander SKUnidrive M700Unidrive M400Powerdrive MD2.

Technical characteristics of network chokes at mains voltage Uin=3~220-480 V 50Hz

type of throttle

     In, And     

   L, MGN  

    N, Tue     

5,5ST4,2

5,5

4,2

36

11ST 2,6

11

2,6

37

21ST1,4

21

1,4

66

29ST1

29

1

69

46ST0,64

46

0,64

99

75ST0,39

75

0,39

135

105ST0,23

105

0,23

170

150ST0,155

150

0,155

190

185ST0,13

185

0,13

200

220ST0,11

220

0,11

230

245ST0,095

245

0,095

245

292ST0,08

292

0,08

280

360ST0,065

360

0,065

310

460ST0,05

460

0,05

350

580ST0,04

580

0,04

490

640ST0,035

640

0,035

515

750ST0,032

750

0,032

625

1000ST0,025

1000

0,025

800

1540ST0,016

1540

0,016

1060


where In is the rated operating current, L is the inductance of the throttle, and P is the loss in the reactor.

Recommendations for using network chokes in conjunction with Leroy Somer electric drives /Control Techniques

type of throttle

type of electric drive

Mentor MP

q-in

Unidrive SP

q-in

Unidirve M701

q-in

5,5 ST 4,2

1,5T /SP 1401

1

M701-034-00025A10

1

11 ST 2,6

2T /SP 1402

2,5T /SP 1403

3,5T /SP 1404

4,5T /SP 1405

1

M701-034-00031A10

M701-034-00045A10

M701-034-00062A10

M701-034-00078A10

1

21 ST 1,4

5,5T /SP 1406

8T /SP 2401

1

M701-034-00100A10

M701-044-00150A10

1

29 ST 1

Mentor MP25A4 (R)

1

11T /SP 2402

16T /SP 2403

20T /SP 2404

1

M701-044-00172A10

M701-054-00270A10

M701-054-00300A10

1

46 ST 0,64

Mentor MP45A4 (R)

1

22T /SP 3401

27T /SP 3402

1

M701-064-00350A10

M701-064-00420A10

1

75 ST 0,39

Mentor MP75A4 (R)

1

33T /SP 3403

40T /SP 4401

1

M701-064-00470A10

M701-074-00660A10

1

105 ST 0,23

50T /SP 4402

60T /SP 4403

1

M701-074-00770A10

M701-074-01000A10

1

150 ST 0,155

Mentor MP105A4 (R)

1

75T /SP 5401

1

M701-084-01340A10

1

185 ST 0,13

Mentor MP155A4 (R)

100T /SP 5402

1

M701-084-01570A10

1

220 ST 0,11

Mentor MP210A4 (R)

1

120T /SP 6401

1

M701-094-02000A10

1

245 ST 0,095

SP 6412, SP 6411

1

292 ST 0,08

150T /SP 6402,

SP 7411

1

M701-094-02240A10

1

360 ST 0,065

Mentor MP350A4 (R)

1

SP 7412, SP 8411

1

460 ST 0,05

Mentor MP420A4 (R)

1

SP 8412

1

580 ST 0,04

Mentor MP550A4 (R)

1

640 ST 0,035

Mentor MP700A4 (R)

1

460 ST 0,05

SP 8413

1

580 ST 0,04

SP 8414

1

640 ST 0,035

SP 9411

1

750 ST 0,032

MP825A4, MP900A4

1

SP 9413

1

1000 ST 0,025

Mentor MP1200A4(R)

1

SP 9414, SP 9415

1

1540 ST 0,016

Mentor MP1850A4(R)

1


Recommendations for using network chokes in conjunction with Leroy Somer electric drives /Control Techniques

type of throttle

type of electric drive

Powerdrive MD2

q-in

Digidrive SK

Commander SK

q-in

Unidirve M400

q-in

5,5 ST 4,2

1T /SKB 3400037

1,5T /SKB 3400075

1

M400-024-00013

M400-024-00023

1

11 ST 2,6

2T /SKB 3400110

2,5T /SKB 3400150

3,5T /SKC 3400220

4,5T /SKC 3400300

1

M400-024-00032

M400-024-00041

M400-034-00056

M400-034-00073

1

21 ST 1,4

5,5T /SKC 3400400

8T /SK 2401

1

M400-034-00094

M400-044-00135

1

29 ST 1

11T /SK 2402

16T /SK 2403

20T /SK 2404

1

M400-044-00170

M400-054-00270

M400-054-00300

1

46 ST 0,64

22T /SK 3401

27T /SK 3402

1

M400-064-00350

M400-064-00420

1

75 ST 0,39

33T /SK 3403

40T /SK 4401

1

M400-064-00470

M400-074-00660

1

105 ST 0,23

60T

1

50T /SK 4402

60T /SK 4403

1

M400-074-00770

M400-074-01000

1

150 ST 0,155

75T

1

75T /SK 5401

1

M400-084-01340

1

185 ST 0,13

100T

1

100T /SK 5402

1

M400-084-01570

1

220 ST 0,11

120T

1

120T /SK 6401

1

M400-094-02000

1

245 ST 0,095

150T

1

SP 6412, SK 6411

1

292 ST 0,08

180T

1

150T /SK 6402

1

M400-094-02240

1

360 ST 0,065

220T

1

460 ST 0,05

270T

1

580 ST 0,04

340T

1

640 ST 0,035

400T

1

460 ST 0,05

470T

2

580 ST 0,04

600T

2

640 ST 0,035

750T

2

750 ST 0,032

1000 ST 0,025

1540 ST 0,016

Features
Brand
No reviews yet — yours could be the first.
All reviews 0
overall rating
Список отзывов пуст