Write to
WhatsApp
Catalog

Выключатель автоматический 100А 36кА NSX250F MICROLOGIC 2.2 электронный расцепитель (LV431772)

For comparison
To favorites
Vendor code:LV431772
-100%
Выключатель автоматический 100А 36кА NSX250F MICROLOGIC 2.2 электронный расцепитель (LV431772)
Brand
Pre-order
$0$5.75
11
Delivery across Russia
On-line payment on the website
Discount system
Purchase returns
Description
Features
Reviews

Main Features

range Compact
Product name Compact NSX
the type of device or its accessories Automatic switch
short name of the device Compact NSX250F
Scope of application Distribution
description of the poles 3P
description of the protected poles 3t
network type Alternating current
network frequency 50/60 Hz
[In] rated current 250 A ( 40 °C )
[Ui] rated insulation voltage 800 V AC 50/60 Hz
[Up] rated pulse withstand voltage 8 kV
[Ue] rated operating voltage 690 V alternating current 50/60 Hz
breaking capacity code F (36 kA) alternating current
breaking capacity 8 kA Icu at 660/690 V AC 50/60 Hz according to IEC 60947-2
22 kA Icu at 525 V AC 50/60 Hz according to IEC 60947-2
35 kA Icu at 440 V AC 50/60 Hz according to IEC 60947-2
36 kA Icu at 380/415 V AC 50/60 Hz according to IEC 60947-2
85 kA Icu in 220/240 V AC 50/60 Hz according to IEC 60947-2
30 kA Icu at 500 V AC 50/60 Hz according to IEC 60947-2
15 kA to 600 V AC 50/60 Hz according to UL 508
35 kA to 480 V alternating current 50/60 Hz according to UL 508
85 kA to 240 V alternating current 50/60 Hz according to UL 508
[Ics] rated operating breaking capacity ICS 22 kA 525 V alternating current 50/60 Hz in accordance with IEC 60947-2
ICS 30 kA 500 V alternating current 50/60 Hz in accordance with IEC 60947-2
ICS 35 kA 440 V alternating current 50/60 Hz in accordance with IEC 60947-2
ICS 36 kA 380/415 V AC 50/60 Hz according to IEC 60947-2
ICS 8 kA 660/690 V AC 50/60 Hz according to IEC 60947-2
ICS 85 kA 220/240 V AC 50/60 Hz according to IEC 60947-2
compliance with insulation requirements Yes according to EN 60947-2
Yes in accordance with IEC 60947-2
Application category Category A
name of the control unit Micrologic 2.2
technology of the control and management unit Electronic
protective functions of the control unit LSoI
rated current of the decoupler 100 A ( 40 °C )
types of implemented protections Instant short circuit protection
Overload protection (with long time delay)
Short circuit protection with short time delay
degree of contamination 3 in accordance with IEC 60664-1

Additional features

management method Toggle switch
switch design Stationary
mounting support Rear mounting plate
connection from the upper side The front one
connection from the bottom side The front one
vspom. contacts available on each contactor Without
mechanical wear resistance 20000 cycles
electrical wear resistance 10000 cycles of 440 V In according to IEC 60947-2
10000 cycles 690 V In/2 in accordance with IEC 60947-2
20000 cycles 440 V In/2 in accordance with IEC 60947-2
5000 cycles 690 V In according to IEC 60947-2
connection step 35 mm
local indication LED "105 % Ir"
LED "90% Ir"
The LED is "ready to work"
protection setpoint with a long delay in the operation of the Ir 9 adjustable. settings
[Ir] overload protection trip current setpoint 0,9...1 x Io
the type of adjustment of the overload response time delay Fixed
[tr] adjustable overload protection time setting 11 with 7.2 x Ir
16 with 6 x Ir
400 with 1.5 x Ir
thermal memory 20 minutes before and after activation
Isd short circuit protection setpoint range 9 adjustable. settings
[Isd] short circuit actuation current setpoint 1.5...10 x Ir
type of short circuit protection response time setting Fixed
The range of instantaneous protection settings of type Ii Fixed
the setpoint of the instantaneous response current 1500 A
height 161 mm
width 105 mm
depth 86 mm
Product weight 2.4 kg

Operating conditions

Overvoltage category Class II
protection class against electric shock Class II
standards EN/IEC 60947
UL 508
Product certification CCC
Marine version
EAC
degree of IP protection IP40 in accordance with IEC 60529
degree of protection IK IK07 in accordance with IEC 62262
Ambient operating temperature -35...70 °C
ambient temperature during storage
Features
Brand
No reviews yet — yours could be the first.
All reviews 0
overall rating
Список отзывов пуст