Main Features

range Compact
Product name Compact NSX
the type of device or its accessories Automatic switch
short name of the device Compact NSX100H
Scope of application Engine
description of the poles 3P
description of the protected poles 3t
network type Alternating current
network frequency 50/60 Hz
[In] rated current 100 A ( 40 °C )
100 A ( 65 °C )
[Ui] rated insulation voltage 800 V AC 50/60 Hz
[Up] rated pulse withstand voltage 8 kV
[Ue] rated operating voltage 690 V alternating current 50/60 Hz
breaking capacity code H (70 kA) alternating current
breaking capacity 50 kA Icu at 500 V AC 50/60 Hz according to IEC 60947-2
10 kA Icu at 660/690 V AC 50/60 Hz according to IEC 60947-2
35 kA Icu at 525 V AC 50/60 Hz according to IEC 60947-2
65 kA Icu in 440 V AC 50/60 Hz according to IEC 60947-2
70 kA Icu at 380/415 V AC 50/60 Hz according to IEC 60947-2
100 kA Icu in 220/240 V AC 50/60 Hz according to IEC 60947-2
10 kA to 600 V AC 50/60 Hz according to UL 508
65 kA to 480 V alternating current 50/60 Hz according to UL 508
85 kA to 240 V alternating current 50/60 Hz according to UL 508
[Ics] rated operating breaking capacity ICS 10 kA 660/690 V AC 50/60 Hz according to IEC 60947-2
ICS 100 kA 220/240 V AC 50/60 Hz according to IEC 60947-2
ICS 35 kA 525 V alternating current 50/60 Hz in accordance with IEC 60947-2
ICS 50 kA 500 V alternating current 50/60 Hz in accordance with IEC 60947-2
ICS 65 kA 440 V alternating current 50/60 Hz in accordance with IEC 60947-2
ICS 70 kA 380/415 V AC 50/60 Hz according to IEC 60947-2
compliance with insulation requirements Yes according to EN 60947-2
Yes in accordance with IEC 60947-2
Application category Category A
name of the control unit BUT
technology of the control and management unit Magnetic
protective functions of the control unit I
rated current of the decoupler 50 A ( 65 °C )
types of implemented protections Short circuit protection (electromagnetic release)
degree of contamination 3 in accordance with IEC 60664-1

Additional features

management method Toggle switch
switch design Stationary
mounting support Rear mounting plate
connection from the upper side The front one
connection from the bottom side The front one
mechanical wear resistance 50000 cycles
electrical wear resistance 10000 cycles of 690 V In according to IEC 60947-2
20000 cycles 690 V In/2 in accordance with IEC 60947-2
30000 cycles 440 V In according to IEC 60947-2
50000 cycles of 440 V In/2 in accordance with IEC 60947-2
connection step 35 mm
local indication Direct indication of the contact position
Isd short circuit protection setpoint range 9 adjustable. settings
[Isd] short circuit actuation current setpoint 6...14 x In
height 161 mm
width 105 mm
depth 86 mm
Product weight 2.05 kg

Operating conditions

Overvoltage category Class II
protection class against electric shock Class II
standards EN/IEC 60947
UL 508
Product certification CCC
Marine version
EAC
degree of IP protection IP40 in accordance with IEC 60529
degree of protection IK IK07 in accordance with IEC 62262
Ambient operating temperature -35...70 °C
ambient temperature during storage -55...85 °C