Write to
WhatsApp
Catalog

Выключатель автоматический 48-80А для защиты электродвигателей с комбинированным расцепителем управление флажком винтовые за (GV7RE80)

For comparison
To favorites
Vendor code:GV7RE80
-100%
Выключатель автоматический 48-80А для защиты электродвигателей с комбинированным расцепителем управление флажком винтовые за (GV7RE80)
Brand
Pre-order
$0$6.78
11
Delivery across Russia
On-line payment on the website
Discount system
Purchase returns
Description
Features
Reviews

Main Features

range TeSys
Product name TeSys GV7
short name of the device GV7R
the type of device or its accessories Automatic switch
Scope of application Engine
description of the poles 3P
network type Alternating current
Application category AC-3 in accordance with IEC 60947-4-1
network frequency 50/60 Hz in accordance with IEC 60947-4-1
breaking capacity 8 kA Icu at 660/690 V AC 50/60 Hz according to IEC 60947-2
25 kA Icu at 500 V AC 50/60 Hz according to IEC 60947-2
35 kA Icu at 440 V AC 50/60 Hz according to IEC 60947-2
36 kA Icu at 380/415 V AC 50/60 Hz according to IEC 60947-2
85 kA Icu in 220/240 V AC 50/60 Hz according to IEC 60947-2
[Icu] nominal maximum maximum breaking capacity (per AC) 100% V 220/240 V AC 50/60 Hz according to IEC 60947-2
100 % V 380/415 V AC 50/60 Hz according to IEC 60947-2
50 % V 660/690 V alternating current 50/60 Hz according to IEC 60947-2
100% V 440 V AC 50/60 Hz according to IEC 60947-2
50 % V 500 V alternating current 50/60 Hz according to IEC 60947-2
rated current of the decoupler 48...80 A
technology of the control and management unit Thermomagnetic

Additional features

switch design Latches
With screws
mounting support Drowned
Panel mounting
The rail
Switchgear mounting kit
mounting position Vertical
engine power, kW 37 kW in 400...415 V alternating current 50/60 Hz
45 kW V 500 V alternating current 50/60 Hz
55 kW V 500 V alternating current 50/60 Hz
55 kW in 660...690 V alternating current 50/60 Hz
management method Control lever
[Ue] rated operating voltage 690 V alternating current 50/60 Hz in accordance with IEC 60947-2
[Ui] rated insulation voltage 750 V AC 50/60 Hz according to IEC 60947-2
[Ith] conditional thermal current in the open air 80 A in accordance with IEC 60947-4-1
[Up] rated pulse withstand voltage 8 kV in accordance with IEC 60947-2
power dissipation 5 Watts
power dissipated by one pole 5 Watts
mechanical wear resistance 50000 cycles
electrical wear resistance 30,000 cycles for AC-3 in 440 V In
50000 cycles for AC-3 in 440 V In/2
Operating frequency 25 cycle/h
standard application Continuous in accordance with IEC 60947-4-1
the interpolar step 35 mm without pole extenders
45 mm with pole extenders
accessions Tires
Cable with a tip - outer diameter: 10 mm
Clamps for bare conductors 1.5...95 mm2
By screw
tightening torque 10 N-m - by screw - screw M6
15 N-m - clips for bare conductors- cable 1.5...95 mm2
mechanical resistance Shocks of 15 g (nom.) for 11 ms in accordance with IEC 60068-2-27
Vibrations 2.5 g (nom.), 0...25 Hz in accordance with IEC 60068-2-6
compliance with insulation requirements Yes in accordance with IEC 60947-1
sensitivity to phase breakage Yes according to IEC 60947-4-1 § 7-2-1-5-2
height 125 mm
width 105 mm
depth 111 mm
Product weight 2.04 kg

Operating conditions

standards EN/IEC 60947-1
EN/IEC 60947-2
EN/IEC 60947-4-1
NF C 63-120
NF C 63-650
NF C 79-130
VDE 0113
VDE 0660
Product certification DNV
UL
protective design TC
degree of IP protection IP405 with terminal covers in accordance with IEC 60529
degree of contamination 3
Ambient operating temperature -25...70 °C
ambient temperature during storage -55...95 °C
Fire resistance 960 °C in accordance with IEC 60695-2-1
working height 2000 m

Features
Brand
No reviews yet — yours could be the first.
All reviews 0
overall rating
Список отзывов пуст