Write to
WhatsApp
Catalog

Выключатель автоматический 4P4D TM160D VIGI MH NSX160B (LV430360)

For comparison
To favorites
Vendor code:LV430360
-100%
Выключатель автоматический 4P4D TM160D VIGI MH NSX160B (LV430360)
Brand
Pre-order
$0$11.73
11
Related files
Delivery across Russia
On-line payment on the website
Discount system
Purchase returns
Description
Features
Reviews

Main Features

range Compact
Product name Compact NSX
the type of device or its accessories Circuit breaker with Vigi add-on
short name of the device VigiCompact NSX160B
Scope of application Distribution
description of the poles 4P
description of the protected poles 4t
neutral position Leftward
network type Alternating current
network frequency 50/60 Hz
[In] rated current 160 A ( 40 °C )
[Ui] rated insulation voltage 800 V AC 50/60 Hz
[Up] rated pulse withstand voltage 8 kV
[Ue] rated operating voltage 440 V alternating current 50/60 Hz
breaking capacity code B (25 kA) alternating current
breaking capacity 25 kA Icu at 380/415 V AC 50/60 Hz according to IEC 60947-2
15 kA Icu in 500 V AC 50/60 Hz according to IEC 60947-2
20 kA Icu at 440 V AC 50/60 Hz according to IEC 60947-2
40 kA Icu in 220/240 V AC 50/60 Hz according to IEC 60947-2
[Ics] rated operating breaking capacity ICS 15 kA 500 V alternating current 50/60 Hz in accordance with IEC 60947-2
ICS 20 kA 440 V alternating current 50/60 Hz in accordance with IEC 60947-2
ICS 25 kA 380/415 V AC 50/60 Hz according to IEC 60947-2
ICS 40 kA 220/240 V AC 50/60 Hz according to IEC 60947-2
compliance with insulation requirements Yes according to EN 60947-2
Yes in accordance with IEC 60947-2
Application category Category A
name of the control unit TM-D
technology of the control and management unit Thermomagnetic
protective functions of the control unit That
rated current of the decoupler 160 A ( 40 °C )
types of implemented protections Overload protection (thermal)
Short circuit protection (electromagnetic release)
name of the additional leakage current protection module MH
degree of contamination 3 in accordance with IEC 60664-1

Additional features

management method Toggle switch
switch design Stationary
mounting support Rear mounting plate
connection from the upper side The front one
connection from the bottom side The front one
mechanical wear resistance 40000 cycles
electrical wear resistance 10000 cycles 440 V In/2 in accordance with IEC 60947-2
15000 cycles 690 V In/2 in accordance with IEC 60947-2
20000 cycles 440 V In according to IEC 60947-2
7500 cycles 690 V In according to IEC 60947-2
connection step 35 mm
local indication Direct indication of the contact position
neutral protection setpoint 1 x Ir 4t
protection setpoint with a long delay in the operation of the Ir Adjustable
[Ir] overload protection trip current setpoint 0,7...1 x In
the type of adjustment of the overload response time delay Fixed
[tr] adjustable overload protection time setting 15 with 6 x Ir
120...400 with 1.5 x In
Isd short circuit protection setpoint range Fixed
[Isd] short circuit actuation current setpoint 1250 A
type of short circuit protection response time setting Fixed
leakage current protection class Class A
earth fault protection With
the type of setpoint of the tripping current protection against leakage currents 5 adjustable. settings
[IΔn] adjustment range of the setpoint of the earth leakage protection operation current 0.03...10 A
the type of setpoint of the time of operation of the protection against leakage currents 4 adjustable. settings
height 236 mm
width 140 mm
depth 86 mm
Product weight 2.6 kg

Operating conditions

Overvoltage category Class II
protection class against electric shock Class II
standards EN/IEC 60947
Product certification CCC
Marine version
EAC
degree of IP protection IP40 in accordance with IEC 60529
degree of protection IK IK07 in accordance with IEC 62262
Ambient operating temperature -35...70 °C
ambient temperature during storage -55...85 °C

Features
Brand
No reviews yet — yours could be the first.
All reviews 0
overall rating
Список отзывов пуст