Write to
WhatsApp
Catalog

Выключатель автоматический четырехполюсный 63A B iC60H (A9F88463)

For comparison
To favorites
Vendor code:A9F88463
-100%
Выключатель автоматический четырехполюсный 63A B iC60H (A9F88463)
Brand
Pre-order
$0$2.72
11
Delivery across Russia
On-line payment on the website
Discount system
Purchase returns
Description
Features
Reviews

Main Features

Scope of application Distribution
range Acti 9
Product name Acti 9 iC60
the type of device or its accessories Miniature circuit breaker
short name of the device IC60H
description of the poles 4P
number of protected poles 4
[In] rated current 63 A
network type Alternating current
Direct current
technology of the control and management unit Thermomagnetic
curve code B
breaking capacity 10 kA Icu according to EN/IEC 60947-2 - 440 V AC 50/60 Hz
15 kA Icu in accordance with EN/IEC 60947-2 - 380...415 V alternating current 50/60 Hz
30 kA Icu in accordance with EN/IEC 60947-2 - 220...240 V alternating current 50/60 Hz
15 kA Icu in accordance with EN/IEC 60947-2 - <= 250 V постоянный ток
10000 A Icn conforming to EN/IEC 60898-1 - 400 V AC 50/60 Hz
42 kA Icu conforming to EN/IEC 60947-2 - 12...60 V AC 50/60 Hz
42 kA Icu conforming to EN/IEC 60947-2 - 100...133 V AC 50/60 Hz
Application category Category A according to EN 60947-2
Category A according to IEC 60947-2
compliance with insulation requirements Yes according to EN 60947-2
Yes according to IEC 60947-2
Yes according to EN 60898-1
Yes in accordance with IEC 60898-1
standards EN 60898-1
EN 60947-2
IEC 60898-1
IEC 60947-2

Additional features

network frequency 50/60 Hz
electromagnetic shutdown limit 4 x In +/- 20 %
[Ics] rated operating breaking capacity 7500 A 75 % x Icu according to EN 60898-1 - 400 V AC 50/60 Hz
7500 A 75 % x Icu according to IEC 60898-1 - 400 V AC 50/60 Hz
21 kA 50 % x Icu according to IEC 60947-2 - 12 ... 133 V AC 50/60 Hz
21 kA 50 % x Icu according to EN 60947-2 - 12 ... 133 V AC 50/60 Hz
15 kA 100 % x Icu according to IEC 60947-2 - 180...250 V DC
15 kA 100 % x Icu according to EN 60947-2 - 180...250 V DC
5 kA 50 % x Icu according to IEC 60947-2 - 440 V AC 50/60 Hz
15 kA 50% x Icu in accordance with EN 60947-2 - 220...240 V alternating current 50/60 Hz
7.5 kA 50% x Icu in accordance with EN 60947-2 - 380...415 V alternating current 50/60 Hz
5 kA 50 % x Icu according to EN 60947-2 - 440 V alternating current 50/60 Hz
15 kA 50% x Icu in accordance with IEC 60947-2 - 220...240 V alternating current 50/60 Hz
7.5 kA 50% x Icu in accordance with IEC 60947-2 - 380...415 V alternating current 50/60 Hz
restriction class 3 in accordance with EN 60898-1
3 in accordance with IEC 60898-1
[Ui] rated insulation voltage 500 V AC 50/60 Hz according to IEC 60947-2
500 V AC 50/60 Hz according to EN 60947-2
[Up] rated pulse withstand voltage 6 kV in accordance with EN 60947-2
6 kV in accordance with IEC 60947-2
contact position indicator Yes
management method Toggle switch
local indication The trigger indicator
switch design Stationary
mounting support DIN rail
compatibility of the distribution unit with comb tires Yes upper or lower
9 mm pitch 8
height 85 mm
width 72 mm
depth 78.5 mm
Product weight 0.5 kg
colour White
mechanical wear resistance 20000 cycles
electrical wear resistance 10000 cycles
accessions Single terminal, upper or lower hard wire (-a) 1...35 mm2 max
Single terminal, upper or lower flexible wire (-a) 1...25 mm2 max
wire stripper length 14 mm upper or lower
tightening torque 3.5 N-m upper or lower
earth fault protection A separate block

Operating conditions

degree of IP protection IP20 according to EN 60529
IP20 according to IEC 60529
degree of contamination 3 in accordance with EN 60947-2
3 in accordance with IEC 60947-2
Overvoltage category IV
preparing for work in tropical conditions 2 in accordance with IEC 60068-1
relative humidity 95 % ( 55 °C )
working height 0...2000 m
Ambient operating temperature -35...70 °C
ambient temperature during storage -40...85 °C

Features
Brand
No reviews yet — yours could be the first.
All reviews 0
overall rating
Список отзывов пуст