Write to
WhatsApp
Catalog

Выключатель автоматический NSX400H MICROLOGIC 1.3 M 320A 3P3D электронный расцепитель (LV432750)

For comparison
To favorites
Vendor code:LV432750
-100%
Выключатель автоматический NSX400H MICROLOGIC 1.3 M 320A 3P3D электронный расцепитель (LV432750)
Brand
Pre-order
$0$13.39
11
Related files
Delivery across Russia
On-line payment on the website
Discount system
Purchase returns
Description
Features
Reviews

Main Features

range Compact
Product name Compact NSX
the type of device or its accessories Automatic switch
short name of the device Compact NSX400H
Scope of application Engine
description of the poles 3P
description of the protected poles 3t
network type Alternating current
network frequency 50/60 Hz
[In] rated current 320 A ( 65 °C )
400 A ( 40 °C )
[Ui] rated insulation voltage 800 V AC 50/60 Hz
[Up] rated pulse withstand voltage 8 kV
[Ue] rated operating voltage 690 V alternating current 50/60 Hz
breaking capacity code H (70 kA) alternating current
breaking capacity 50 kA Icu at 500 V AC 50/60 Hz according to IEC 60947-2
35 kA Icu at 525 V AC 50/60 Hz according to IEC 60947-2
65 kA Icu in 440 V AC 50/60 Hz according to IEC 60947-2
70 kA Icu at 380/415 V AC 50/60 Hz according to IEC 60947-2
100 kA Icu in 220/240 V AC 50/60 Hz according to IEC 60947-2
20 kA Icu at 660/690 V AC 50/60 Hz according to IEC 60947-2
20 kA to 600 V AC 50/60 Hz according to UL 508
65 kA to 480 V alternating current 50/60 Hz according to UL 508
85 kA to 240 V alternating current 50/60 Hz according to UL 508
[Ics] rated operating breaking capacity ICS 10 kA 660/690 V AC 50/60 Hz according to IEC 60947-2
ICS 100 kA 220/240 V AC 50/60 Hz according to IEC 60947-2
ICS 11 kA 525 V alternating current 50/60 Hz in accordance with IEC 60947-2
ICS 50 kA 500 V alternating current 50/60 Hz in accordance with IEC 60947-2
ICS 65 kA 440 V alternating current 50/60 Hz in accordance with IEC 60947-2
ICS 70 kA 380/415 V AC 50/60 Hz according to IEC 60947-2
compliance with insulation requirements Yes according to EN 60947-2
Yes in accordance with IEC 60947-2
Application category Category A
name of the control unit Micrologic 1.3 M
technology of the control and management unit Electronic
protective functions of the control unit I
rated current of the decoupler 320 A ( 65 °C )
types of implemented protections Short circuit protection (electromagnetic release)
degree of contamination 3 in accordance with IEC 60664-1

Additional features

management method Toggle switch
switch design Stationary
mounting support Rear mounting plate
connection from the upper side The front one
connection from the bottom side The front one
mechanical wear resistance 15000 cycles
electrical wear resistance 12000 cycles 440 V In/2 in accordance with IEC 60947-2
3000 cycles 690 V In according to IEC 60947-2
6000 cycles 440 V In according to IEC 60947-2
6000 cycles 690 V In/2 in accordance with IEC 60947-2
connection step 45 mm
local indication The LED is "ready to work"
Isd short circuit protection setpoint range 9 adjustable. settings
[Isd] short circuit actuation current setpoint 1600 A
1920 A
2440 A
2560 A
2880 A
3200 A
3520 A
3840 A
4160 A
type of short circuit protection response time setting Fixed
The range of instantaneous protection settings of type Ii Fixed
the setpoint of the instantaneous response current 4800 A
height 255 mm
width 140 mm
depth 110 mm
Product weight 6.05 kg

Operating conditions

Overvoltage category Class II
protection class against electric shock Class II
standards EN/IEC 60947
UL 508
Product certification CCC
Marine version
EAC
degree of IP protection IP40 in accordance with IEC 60529
degree of protection IK IK07 in accordance with IEC 62262
Ambient operating temperature -35...70 °C
ambient temperature during storage -55...85 °C

Features
Brand
No reviews yet — yours could be the first.
All reviews 0
overall rating
Список отзывов пуст