Main Features

range Compact
Product name Compact NSX
the type of device or its accessories Automatic switch
short name of the device Compact NSX630N
Scope of application Distribution
description of the poles 3P
description of the protected poles 3t
network type Alternating current
network frequency 50/60 Hz
[In] rated current 630 A ( 40 °C )
[Ui] rated insulation voltage 800 V AC 50/60 Hz
[Up] rated pulse withstand voltage 8 kV
[Ue] rated operating voltage 690 V alternating current 50/60 Hz
breaking capacity code N (50 kA) alternating current
breaking capacity 10 kA Icu at 660/690 V AC 50/60 Hz according to IEC 60947-2
22 kA Icu at 525 V AC 50/60 Hz according to IEC 60947-2
85 kA Icu in 220/240 V AC 50/60 Hz according to IEC 60947-2
30 kA Icu at 500 V AC 50/60 Hz according to IEC 60947-2
42 kA Icu in 440 V AC 50/60 Hz according to IEC 60947-2
50 kA Icu at 380/415 V AC 50/60 Hz according to IEC 60947-2
20 kA to 600 V AC 50/60 Hz according to UL 508
50 kA to 480 V alternating current 50/60 Hz according to UL 508
85 kA to 240 V alternating current 50/60 Hz according to UL 508
[Ics] rated operating breaking capacity ICS 10 kA 660/690 V AC 50/60 Hz according to IEC 60947-2
ICS 11 kA 525 V alternating current 50/60 Hz in accordance with IEC 60947-2
ICS 30 kA 500 V alternating current 50/60 Hz in accordance with IEC 60947-2
ICS 42 kA 440 V alternating current 50/60 Hz in accordance with IEC 60947-2
ICS 50 kA 380/415 V AC 50/60 Hz according to IEC 60947-2
ICS 85 kA 220/240 V AC 50/60 Hz according to IEC 60947-2
compliance with insulation requirements Yes according to EN 60947-2
Yes in accordance with IEC 60947-2
Application category Category A
name of the control unit Micrologic 5.3 A
technology of the control and management unit Electronic
protective functions of the control unit LSI
rated current of the decoupler 630 A ( 40 °C )
types of implemented protections Instant short circuit protection
Overload protection (with long time delay)
Short circuit protection with short time delay
degree of contamination 3 in accordance with IEC 60664-1

Additional features

management method Toggle switch
switch design Stationary
mounting support Rear mounting plate
connection from the upper side The front one
connection from the bottom side The front one
vspom. contacts available on each contactor Without
mechanical wear resistance 15000 cycles
electrical wear resistance 2000 cycles of 690 V In according to IEC 60947-2
4000 cycles 440 V In according to IEC 60947-2
6000 cycles 690 V In/2 in accordance with IEC 60947-2
8000 cycles 440 V In/2 in accordance with IEC 60947-2
connection step 45 mm
local indication LED "105 % Ir"
LED "90% Ir"
The LED is "ready to work"
protection setpoint with a long delay in the operation of the Ir Adjustable
[Ir] overload protection trip current setpoint 225...630 A
the type of adjustment of the overload response time delay Adjustable.
[tr] adjustable overload protection time setting 15...400 with 1.5 x Ir
0.35...11 with 7.2 x Ir
0.5...16 with 6 x Ir
thermal memory 20 minutes before and after activation
Isd short circuit protection setpoint range Adjustable.
[Isd] short circuit actuation current setpoint 1.5...10 x Ir
type of short circuit protection response time setting Adjustable
[tsd] short circuit response time adjustment range 0...0.4 s
The range of instantaneous protection settings of type Ii Adjustable
the setpoint of the instantaneous response current 1,5...11 x In
logical selectivity of ZCI With
data exchange Current and power consumption
Energy calculation
Instantaneous values and consumption values
Indicators of the need for maintenance
Display min./max. values
Power supply quality
Protection and alarm settings
Logs and tables of events with timestamps
display type LCD display
type of measurements Ammeter
stored electrical parameters Indicators of the need for maintenance
height 255 mm
width 140 mm
depth 110 mm
Product weight 6.2 kg

Operating conditions

Overvoltage category Class II
protection class against electric shock Class II
standards EN/IEC 60947
UL 508
Product certification CCC
Marine version
EAC
degree of IP protection IP40 in accordance with IEC 60529
degree of protection IK IK07 in accordance with IEC 62262
Ambient operating temperature -35...70 °C
ambient temperature during storage -55...85 °C