Description
Features
Reviews
Main Features
product series | The sensor of the Preventa security system | |
---|---|---|
the type of device or its accessories | Safety relay | |
name of the component | XCSE | |
construction | Rectangular | |
material | Metal | |
type of head | Revolver head with key | |
type of contacts | 3 N. S. | |
the work of contacts | Slow opening, instantaneous | |
type and composition of electromagnet contacts | 1 NC + 1 NO (slow opening, instantaneous) | |
cable entry | 2 inputs with Pg 13.5 thread | |
electromagnetic blocking | Locking when applying and unlocking when removing voltage from the solenoid | |
[Us] rated mains voltage | 110/120 V (- 20...10 %) | |
the outer diameter of the cable | 9...12 mm | |
electrical connection | Clamp, 1 x 0.5...2 x 1.5 mm2 with or without cable tip | |
number of poles | 3 | |
description of the blocking parameters | With blocking by means of an electromagnetic relay | |
local indication | 1 LED is green (the fence is closed and locked) | |
alarm circuit voltage | 110/240 V (voltage limits: 95...264 V) |
Additional features
direct opening | With N.Z. contact | |
---|---|---|
Type of supply voltage | Per./post. current | |
frequency | 50/60 Hz | |
load factor | 1 | |
power consumption, VA | 10 V·A (throw) 10 V·A (sealed) |
|
type of alarm circuit | Per. current | |
alarm circuit consumption | 7 mA | |
mechanical wear resistance | >=1000000 cycles | |
min. activation speed | 0.01 m/s | |
max. activation speed | 0.5 m/s | |
[Icw] rated short-term permissible current | 0.55 A at 125 V usage category DC-13, Q300 according to EN/IEC 60947-5-1 0.27 A at 250 V usage category DC-13, Q300 according to EN/IEC 60947-5-1 3 A at 120 V AC 50/60Hz usage category AC-15, B300 according to EN/IEC 60947-5-1 1.5A at 240 V usage category AC-15, B300 according to EN/IEC 60947-5-1 |
|
[Ithe] conditional thermal current in a closed case | 6 A | |
[Ui] rated insulation voltage | 250 V for alarm circuit according to EN/IEC 60947-1 | |
[Up] rated pulse withstand voltage | 6 kV in accordance with EN/IEC 60947-5-1 | |
types of implemented protections | Surge protection for alarm circuit | |
?????? ?? ????????? ????????? | 10 A fuse box type gG (gl) | |
forced removal of the executive element | 2000 N | |
the extraction force of the actuating element | >=20 N | |
Operating frequency | 10 cycle/m for maximum wear resistance | |
security level | It can reach category 4 with an appropriate control system and properly executed wiring in accordance with EN/ISO 13849-1 It can reach PL=e with an appropriate control system and properly executed wiring in accordance with EN/ISO 13849-1 It can reach SIL 3 with an appropriate monitoring system and properly executed wiring in accordance with EN/IEC 61508 |
|
safety and reliability data | B10d=5000000 (value set for a service life of 20 years, limited by mechanical or contact wear) | |
housing material | Zamak alloy | |
head material | Zamak alloy | |
depth | 44 mm | |
height | 146 mm | |
width | 98 mm | |
Product weight | 1.14 kg |
Operating conditions
standards | EN 1088 /ISO 14119 EN/IEC 60204-1 EN/IEC 60947-5-1 EN /ISO 12100 UL 508 CSA C22.2 № 14 |
|
---|---|---|
Product certification | CSA UL |
|
protective design | TC | |
Ambient operating temperature | -25...40 °C | |
ambient temperature during storage | -40...70 °C | |
vibration resistance | 5 gn (f=10...500 Hz) in accordance with IEC 60068-2-6 | |
Impact resistance | 10 gn for 11 ms in accordance with IEC 60068-2-27 | |
protection class against electric shock. by electric current | Class I according to EN/IEC 61140 | |
degree of IP protection | IP67 according to EN/IEC 60529 and EN/IEC 60947-5-1 |
Environmental friendliness of the offer
RoHS Directive (date format: YYWW, 2 digits of the year and 2 digits of the week number) | Schneider Electric Declaration of Conformity | |
---|---|---|
REACh Regulations | The product does not contain particularly dangerous substances in quantities exceeding the norm. | |
Instructions for disposal of the product | Disposal Guide |
Equipment warranty
Period | The warranty period for this equipment is 18 months from the date of its commissioning, which is confirmed by the relevant document, but not more than 24 months from the date of delivery |
---|