Waterpilot FMX21 Hydrostatic Level Sensor

The Waterpilot FMX21 transmitter with a capacitive, oil-free ceramic measuring cell is typically used in environmental processes and applications to measure the hydrostatic level. With the HART output, the measurement ranges can be freely adjusted, and the density level can be measured with density compensation. It is certified for drinking water and offers integrated temperature measurement. Versions are also available for use in wastewater and sludge or for use in salt water.

Benefits

  •  Durable overload-resistant ceramic sensor of high purity (99.9% Al 2 O 3 )
  •  Flexible scaling from 4 to 20 mA with superimposed HART 6.0 output
  •  The highest level of accuracy using density correction with temperature compensation
  •  Simultaneous measurement of level and temperature using the built-in Pt100 temperature sensor
  •  A wide range of accessories provides complete solutions for measuring points
  •  A climatically tested sensor thanks to fully sealed electronics and a two-component pressure compensation system
  •  Small outer diameter of 22 mm (0.87 in), suitable for use in drinking water and for use in wells and boreholes with small diameters

 

Scope of application

Three different options for drinking water, wastewater and wastewater, salt water.

  •  Process connections: Suspension clamp, cable gland
  •  Temperature: from -10 to + 70 aposematic (from 14 to 158 aposematic)
  •  Measuring range: 0 to 20 bar /200 m H 2 0 (0 to 300 psi /600 ft H 2 O)
  •  Accuracy: ± 0.2%, "platinum" ± 0.1%
  •  International explosion protection certificates, marine certificates, drinking water approval

 

Features and Specifications

The principle of measurement

hydrostatic

Characteristic /Application

Compact probe with ceramic cell for hydrostatic level measurement, 
Diameter=22 mm: General applications, Fresh water 
Diameter=42 mm: Wastewater application 
Diameter=29 mm: Salt water application 

Specialties

Automatic density compensation 
Execution without metal parts in contact with the process

Delivery /Communication

10,5 ... 35 V DC 

accuracy

0,2% 
0.1% (optional) 

Long-term stability

0.1% URL /year 

Ambient temperature

From -10 ° C ... 70 ° C 
(14 ° F ... 158 ° F) 
Diameter 29mm (1.14"): 
From 0 ° C ... 50 ° C 
(32 ° F ... 122 ° F) 

Process temperature

From -10 ° C ... 70 ° C 
(14 ° F ... 158 ° F) 
Диаметр 29 мм (1,14 "): 0 ° C ... 50 ° C 
(32 ° F ... 122 ° F) 

Pressure measurement range

100 mbar ... 20 bar 
(1,5 psi ... 300 psi) 

Main wetted parts

22mm and 42mm Diameter: Seal, 316L, Ceramic 
Diameter 29 mm: seal, PPS, polyolefin, ceramic 
Extension cable: PE, PUR, FEP 

Joining the process

Hanging clamp 
Screws for fixing the cable 

Maximum. Measuring distance

200 m H2O 
(656 ft H2O) 

connection

4 ... 20 mA 
4 ... 20 mA HART 

Certificates /Permissions

ATEX, FM, CSA, CSA C /US, IEC Ex, NEPSI 

Approval of marine vessels

GL /ABS /BV /DNV 

Drinking water permits

KTW /NSF /ACS 

Options

Absolute measuring cell 
Built-in Pt100 temperature sensor, 4-wire 
Customizing the client 
Individual cable marking 

Limits of application

Measuring cell: ceramic 

 

 

Features