Bypass valves designed to protect against exceeding the maximum permissible operating pressure of various technological equipment, pumps, valves, etc.
The bypass valve is designed to prevent accidents and failures in the robot equipment caused by hydraulic shocks.
The hygienic stainless steel valve 74700 is widely used with equipment in the food, dairy, pharmaceutical, and fine chemicals industries in order to protect equipment.
The principle of operation
During normal operation, the valve is closed.
Valve it is calibrated to a certain pressure by adjusting the spring with a nut. The calibrated pressure is the maximum allowable pressure for safe operation of the equipment.
When the pressure in the system rises above the operating pressure, the safety valve opens, allowing the flow of the medium and thereby reducing the pressure in the system.
The operation of the bypass valve can be adjusted