Description
Features
Reviews
Main Features
range | TeSys | |
---|---|---|
Product name | TeSys B | |
the type of device or its accessories | Contactor | |
short name of the device | LC1BL | |
contactor application | Engine-heating-lighting | |
Application category | AC-1 AC-3 AC-4 |
|
type of control circuit | Per. current | |
coil type | Standard | |
description of the poles | 3P | |
configuration of the main contacts | 3 N.O. | |
[Icw] rated short-term permissible current | 800 A (<= 40 °C) переменный ток AC-1 для силовая цепь 750 A (<= 55 °C) переменный ток AC-3 для силовая цепь |
|
engine power, kW | 220 kW 220...230 V alternating current 50/60 Hz AC-3 400 kW in 380...400 V alternating current 50/60 Hz AC-3 425 kW to 415 V AC 50/60 Hz AC-3 450 kW V 440 V AC 50/60 Hz AC-3 500 kW at 500 V AC 50/60 Hz AC-3 530 kW at 1000 V AC 50/60 Hz AC-3 560 kW at 660...690 V AC 50/60 Hz AC-3 160 kW at 400 V AC 50/60 Hz AC-4 |
|
vspom. contacts available on each contactor | 2 N.O. + 2 N.Z. | |
control circuit voltage | 220 V lane The current is 50...400 Hz |
Additional features
voltage limits of the control circuit | 0.3...0.5 Uc release 50...400 Hz 0.85...1.1 Uc is in operation state 50...400 Hz |
|
---|---|---|
[Ui] rated insulation voltage | 1000 V - for power circuit - conforming to IEC 60158-1 1000 V - for power circuit - conforming to IEC 60947-4 1500 V - for power circuit - corresponding to VDE 0110 group C |
|
switch design | Stationary | |
mounting support | Tire support bracket Perforated mounting rails |
|
tightening torque | Power circuit- : 21 N-m - tires | |
[Ue] rated operating voltage | <= 1000 V переменный ток 50/60 Гц для силовая цепь | |
[Ith] conditional thermal current in the open air | 800 A V <= 40 °C для силовая цепь | |
Rated switching capacity of Irms | 10000 A at 1000 V alternating current for a power circuit according to IEC 60158-1 10000 A at 1000 V alternating current for a power circuit according to IEC 60947-4 |
|
rated breaking capacity | 10000 A at 440 V for a power circuit according to IEC 60158-1 10000 A at 440 V for a power circuit according to IEC 60947-4 4000 A at 1000 V for a power circuit according to IEC 60158-1 4000 A at 1000 V for a power circuit according to IEC 60947-4 8000 A at 660...690 V for power circuit according to IEC 60158-1 8000 A at 660...690 V for power circuit according to IEC 60947-4 9000 A at 500 V for a power circuit according to IEC 60158-1 9000 A at 500 V for a power circuit according to IEC 60947-4 |
|
the corresponding fuse rating | 1000 A gI in <= 440 V для силовая цепь 800 A aM V <= 440 V для силовая цепь 800 A gI in <= 440 V для силовая цепь |
|
average total resistance | 0.18mOhm at 50 Hz - Ith 800 A for power circuit- | |
power dissipated by one pole | 115 W AC-1 - Ith 800 A 88 W AC-3 - Ith 800 A |
|
power consumption when triggered | 1300 VA | |
power consumption during holding, V·A | 31 VA 50/60 Hz | |
Response time | 100...150 ms switching on 50...100 ms shutdown |
|
mechanical wear resistance | 1200000 cycles | |
Operating frequency | 120 cycle/h at <= 55 °C | |
height | 486 mm | |
width | 570 mm | |
depth | 475 mm | |
Product weight | 58 kg |
Operating conditions
standards | BS 5424 IEC 60158-1 IEC 60947-4 NF C 63-110 VDE 0660 |
|
---|---|---|
Product certification | BV CSA RINA |
|
protective design | TC TH |
|
Ambient operating temperature | -5...55 °C | |
ambient temperature during storage | -60...80 °C | |
working height | 3000 m without temperature degradation |
Features
Brand
Schneider
No reviews yet — yours could be the first.
All reviews 0
Список отзывов пуст