Main Features
range | TeSys | |
---|---|---|
Product name | TeSys D | |
the type of device or its accessories | Contactor switch | |
short name of the device | LC2D | |
contactor application | Active load | |
Application category | AC-1 | |
Product configuration | Preassembled, with prewired power connections | |
description of the poles | 4P | |
configuration of the main contacts | 4 N.O. | |
[Ue] rated operating voltage | <= 300 В постоянный ток для силовая цепь <= 690 V переменный ток 25...400 Hz для силовая цепь |
|
[Icw] rated short-term permissible current | 25 A (<= 60 °C) в <= 440 V переменный ток AC-1 для силовая цепь | |
type of control circuit | Post. The current is standard | |
control circuit voltage | 24 V post. current | |
vspom. contacts available on each contactor | 1 N.O. + 1 N.Z. | |
[Up] rated pulse withstand voltage | 6 kV in accordance with IEC 60947 | |
Overvoltage category | III | |
[Ith] conditional thermal current in the open air | 25 A B <= 60 °C для силовая цепь 10 A in <= 60 °C для цепь сигнализации |
|
Rated switching capacity of Irms | 250 A to 440 V for power circuit according to IEC 60947 140 A alternating current for alarm circuit according to IEC 60947-5-1 250 A direct current for alarm circuit according to IEC 60947-5-1 |
|
rated breaking capacity | 250 A to 440 V for power circuit according to IEC 60947 | |
[Icw] rated short-term sustained current | 105 A <= 40 °C 10 с силовая цепь 210 A <= 40 °C 1 с силовая цепь 30 A <= 40 °C 10 мин силовая цепь 61 A <= 40 °C 1 мин силовая цепь 100 A 1 s alarm circuit 120 A 500 ms alarm circuit 140 A 100 ms alarm circuit |
|
the corresponding fuse rating | 25 A gG in <= 690 V координация тип 2 для силовая цепь 40 A gG in <= 690 V координация тип 1 для силовая цепь 10 A gG for alarm circuit according to IEC 60947-5-1 |
|
average total resistance | 2.5mOhm V 50 Hz - Ith 25 A for power circuit | |
[Ui] rated insulation voltage | 600 V for CSA certification power circuit 600 V for UL certification power circuit 690 V for power circuit according to IEC 60947-4-1 690 V for alarm circuit according to IEC 60947-1 600 V for CSA certification alarm circuit 600 V for UL certification alarm circuit |
|
electrical wear resistance | 0.8 million cycles of 25 A AC-1 at Ue <= 440 V | |
power dissipated by one pole | 1.56W AC-1 | |
protective cover | With | |
type of blocking | Mechanical | |
mounting support | Panel mounting The rail |
|
standards | CSA C22.2 № 14 EN 60947-4-1 EN 60947-5-1 IEC 60947-4-1 IEC 60947-5-1 UL 508 |
|
Product certification | BV CCC CSA DNV GL GOST LROS (Lloyds register of shipping) RINA UL |
|
accessions | Control circuit : screw clamp 2 cable(s) 1...2.5 mm2 - cable stiffness: flexible - with cable tip Power circuit : screw clamp 1 cable(s) 1...4 mm2 - cable stiffness: flexible - with cable tip Control circuit : screw clamp 1 cable(s) 1...4 mm2 - cable stiffness: flexible - without cable tip Control circuit : screw clamp 2 cable(s) 1...4 mm2 - cable stiffness: flexible - without cable tip Control circuit : screw clamp 1 cable(s) 1...4 mm2 - cable stiffness: flexible - with cable tip Control circuit : screw clamp 1 cable(s) 1...4 mm2 - cable stiffness: rigid cable - without cable tip Control circuit : screw clamp 2 cable(s) 1...4 mm2 - cable stiffness: rigid cable - without cable tip Power circuit : screw clamp 1 cable(s) 1...4 mm2 - cable stiffness: flexible - without cable tip Power circuit : screw clamp 2 cable(s) 1...4 mm2 - cable stiffness: flexible - without cable tip Power circuit : screw clamp 2 cable(s) 1...2.5 mm2 - Cable stiffness: flexible - with cable tip Power circuit : screw clamp 1 cable(s) 1...4 mm2 - cable stiffness: rigid cable - without cable tip Power circuit : screw clamp 2 cable(s) 1...4 mm2 - cable stiffness: rigid cable - without cable tip |
|
tightening torque | Power circuit : 1.7 N-m - screw clamp - flat with a screwdriver. Ø 6 mm Power circuit : 1.7 N-m - screw clamp - using a Philips No. 2 screwdriver Control circuit : 1.7 N-m - screw clamp - flat with a screwdriver. Ø 6 mm Control circuit : 1.7 N-m - screw clamp - using a Philips No. 2 screwdriver |
|
Response time | 53.55...72.45 ms switching on 16...24 ms shutdown |
|
a safe level of reliability | B10d=1369863 cycles contactor with rated load according to EN/ISO 13849-1 B10d=20000000 cycles contactor with mechanical load according to EN/ISO 13849-1 |
|
mechanical wear resistance | 30 million cycles | |
Operating frequency | <= 3600 cyc/h at <= 60 °C |
Additional features
the technology of using coils | Built-in symmetrical protective zener diode | |
---|---|---|
voltage limits of the control circuit | 0.1...0.25 Uc release at 60 °C, direct current 0.7...1.25 Uc is in operation at 60 °C, direct current |
|
the time constant | 28 ms | |
starting power, W | 5.4W at 20 °C | |
power consumption when holding, W | 5.4W at 20 °C | |
the type of vspom. contacts | Type mechanically coupled (1 N.O. + 1 N.Z.) in accordance with IEC 60947-5-1 Type duplicate contact (1 N.Z.) in accordance with IEC 60947-4-1 |
|
alarm circuit frequency | 25...400 Hz | |
minimum switching current | 5 mA for alarm circuit | |
minimum switching voltage | 17 Into the Alarm circuit | |
time without overlap | 1.5 ms when voltage is removed (between NC and NO contact) 1.5 ms when voltage is applied (between NC and NO contact) |
|
insulation resistance | > 10 mOhm for alarm circuit |
Operating conditions
degree of IP protection | IP20 front panel in accordance with IEC 60529 | |
---|---|---|
protective design | TH in accordance with IEC 60068-2-30 | |
degree of contamination | 3 | |
Ambient operating temperature | -5...60 °C | |
ambient temperature during storage | -60...80 °C | |
permissible air temperature around the device | -40...70 °C at Uc | |
working height | 3000 m without temperature degradation | |
Fire resistance | 850 °C in accordance with IEC 60695-2-1 | |
Fire resistance | V1 in accordance with UL 94 | |
mechanical resistance | Vibration contactor is open 2 g (nom.), 5...300 Hz Vibration contactor is closed 4 g (nom.), 5...300 Hz Shocks The contactor is open 10 gn for 11 ms Shocks The contactor is closed 15 g (nom.) for 11 ms |
|
height | 85 mm | |
width | 90 mm | |
depth | 90 mm | |
Product weight | 0.73 kg |