Main Features

range TeSys
Product name TeSys D
the type of device or its accessories Reversible contactor
short name of the device LC2D
contactor application Electric motor control
Active load
Application category AC-1
AC-3
Product configuration Pre-assembled with a power reverse busbar
description of the poles 3P
configuration of the main contacts 3 N.O.
[Ue] rated operating voltage <= 300 В постоянный ток для силовая цепь
<= 690 V переменный ток 25...400 Hz для силовая цепь
[Icw] rated short-term permissible current 38 A (<= 60 °C) в <= 440 V переменный ток AC-3 для силовая цепь
50 A (<= 60 °C) в <= 440 V переменный ток AC-1 для силовая цепь
engine power, kW 18.5 kW in 380...400 V alternating current 50/60 Hz
18.5 kW 500 V AC 50/60 Hz
18.5 kW in 660...690 V alternating current 50/60 Hz
18.5 kW V 415...440 V alternating current 50/60 Hz
9 kW 220...230 V alternating current 50/60 Hz
engine power, hp 10 hp 230/240 V Alternating current 50/60 Hz for 3 Phase electric motors
10 HP 200/208 V Alternating current 50/60 Hz for 3 Phase electric motors
5 HP 240 V AC 50/60 Hz for 1 Phase Electric Motors
20 hp to 480 V Alternating current 50/60 Hz for 3 Phase electric motors
25 hp to 600 V AC 50/60 Hz for 3 Phase Electric motors
type of control circuit Per. Current 50/60 Hz
control circuit voltage 380 V lane Current 50/60 Hz
vspom. contacts available on each contactor 1 N.O. + 1 N.Z.
[Up] rated pulse withstand voltage 6 kV in accordance with IEC 60947
Overvoltage category III
[Ith] conditional thermal current in the open air 50 A in <= 60 °C для силовая цепь
10 A in <= 60 °C для цепь сигнализации
Rated switching capacity of Irms 550 A to 440 V for power circuit according to IEC 60947
140 A alternating current for alarm circuit according to IEC 60947-5-1
250 A direct current for alarm circuit according to IEC 60947-5-1
rated breaking capacity 550 A to 440 V for power circuit according to IEC 60947
[Icw] rated short-term sustained current 150 A <= 40 °C 1 мин силовая цепь
310 A <= 40 °C 10 с силовая цепь
430 A <= 40 °C 1 с силовая цепь
60 A <= 40 °C 10 мин силовая цепь
100 A 1 s alarm circuit
120 A 500 ms alarm circuit
140 A 100 ms alarm circuit
the corresponding fuse rating 63 A gG B <= 690 V координация тип 1 для силовая цепь
63 A gG B <= 690 V координация тип 2 для силовая цепь
10 A gG for alarm circuit according to IEC 60947-5-1
average total resistance 2 mOhm V 50 Hz - Ith 50 A for power circuit
[Ui] rated insulation voltage 600 V for CSA certification power circuit
600 V for UL certification power circuit
690 V for power circuit according to IEC 60947-4-1
690 V for alarm circuit according to IEC 60947-1
600 V for CSA certification alarm circuit
600 V for UL certification alarm circuit
electrical wear resistance 1.4 million cycles of 50 A AC-1 at Ue <= 440 V
1.4 million cycles of 38 A AC-3 at Ue <= 440 V
power dissipated by one pole 3 W AC-3
5W AC-1
protective cover With
type of blocking Mechanical
mounting support Panel mounting
The rail
standards CSA C22.2 № 14
EN 60947-4-1
EN 60947-5-1
IEC 60947-4-1
IEC 60947-5-1
UL 508
Product certification BV
CCC
CSA
DNV
GL
GOST
LROS (Lloyds register of shipping)
RINA
UL
accessions Control circuit : screw clamp 2 cable(s) 1...2.5 mm2 - cable stiffness: flexible - with cable tip
Power circuit : screw clamp 1 cable(s) 1.5...10 mm2 - cable stiffness: rigid cable - without cable tip
Control circuit : screw clamp 1 cable(s) 1...4 mm2 - cable stiffness: flexible - without cable tip
Control circuit : screw clamp 2 cable(s) 1...4 mm2 - cable stiffness: flexible - without cable tip
Control circuit : screw clamp 1 cable(s) 1...4 mm2 - cable stiffness: flexible - with cable tip
Control circuit : screw clamp 1 cable(s) 1...4 mm2 - cable stiffness: rigid cable - without cable tip
Control circuit : screw clamp 2 cable(s) 1...4 mm2 - cable stiffness: rigid cable - without cable tip
Power circuit : screw clamp 1 cable(s) 2.5...10 mm2 - cable stiffness: flexible - without cable tip
Power circuit : screw clamp 2 cable(s) 2.5...10 mm2 - cable stiffness: flexible - without cable tip
Power circuit : screw clamp 1 cable(s) 1...10 mm2 - cable stiffness: flexible - with cable tip
Power circuit : screw clamp 2 cable(s) 1.5...6 mm2 - Cable stiffness: flexible - with cable tip
Power circuit : screw clamp 2 cable(s) 2.5...10 mm2 - cable stiffness: rigid cable - without cable tip
tightening torque Control circuit : 1.7 N-m - screw clamp - flat with a screwdriver. Ø 6 mm
Control circuit : 1.7 N-m - screw clamp - using a Philips No. 2 screwdriver
Power circuit : 2.5 N-m - screw clamp - flat with a screwdriver. Ø 6 mm
Power circuit : 2.5 N-m - screw clamp - using a Philips No. 2 screwdriver
Response time 4...19 ms shutdown
12...22 ms switching on
a safe level of reliability B10d=1369863 cycles contactor with rated load according to EN/ISO 13849-1
B10d=20000000 cycles contactor with mechanical load according to EN/ISO 13849-1
mechanical wear resistance 15 million cycles
Operating frequency 3600 cycle/h in <= 60 °C

Additional features

the technology of using coils Without built-in overload protection module
voltage limits of the control circuit 0.3...0.6 Uc release at 60 °C, alternating current 50/60 Hz
0.8...1.1 Uc is in operation at 60 °C, alternating current 50 Hz
0.85...1.1 Uc is in operation at 60 °C, alternating current 60 Hz
power consumption when triggered 70 V·A at 20 °C (cos ϕ 0.75) 60 Hz
70 V·A at 20 °C (cos ϕ 0.75) 50 Hz
power consumption during holding, V·A 7.5 V·A at 20 °C (cos ϕ 0.3) 60 Hz
7 V·A at 20 °C (cos ϕ 0.3) 50 Hz
heat transfer 2...3 Watts at 50/60 Hz
the type of vspom. contacts Type mechanically coupled (1 N.O. + 1 N.Z.) in accordance with IEC 60947-5-1
Type duplicate contact (1 N.Z.) in accordance with IEC 60947-4-1
alarm circuit frequency 25...400 Hz
minimum switching current 5 mA for alarm circuit
minimum switching voltage 17 Into the Alarm circuit
time without overlap 1.5 ms when voltage is removed (between NC and NO contact)
1.5 ms when voltage is applied (between NC and NO contact)
insulation resistance > 10 mOhm for alarm circuit

Operating conditions

degree of IP protection IP20 front panel in accordance with IEC 60529
protective design TH in accordance with IEC 60068-2-30
degree of contamination 3
Ambient operating temperature -20...60 °C
ambient temperature during storage -60...80 °C
permissible air temperature around the device -40...70 °C at Uc
working height 3000 m without temperature degradation
Fire resistance 850 °C in accordance with IEC 60695-2-1
Fire resistance V1 in accordance with UL 94
mechanical resistance Vibration contactor is open 2 g (nom.), 5...300 Hz
Vibration contactor is closed 4 g (nom.), 5...300 Hz
Shocks The contactor is closed 15 g (nom.) for 11 ms
Shocks The contactor is open 8 g (nom.) for 11 ms
height 85 mm
width 90 mm
depth 92 mm
Product weight 0.807 kg