Write to
WhatsApp
Catalog

LXM28AU15M3X СЕРВОПРЕОБРАЗОВАТЕЛЬ LXM28AU15M3X

For comparison
To favorites
Vendor code:LXM28AU15M3X
-100%
LXM28AU15M3X СЕРВОПРЕОБРАЗОВАТЕЛЬ LXM28AU15M3X
Brand
Pre-order
$0$0.01
11
Related files
Delivery across Russia
On-line payment on the website
Discount system
Purchase returns
Description
Features
Reviews

Main Features

product series Lexium 28
the type of device or its accessories Motion control servo
short name of the device LXM28A
the shape of the drive Compact housing
linear current 10 A, THDI of 144.8% at 220 test3, three-phase
10 A, THDI of 166.6% at 220 test3, single-phase

Additional features

number of network phases Single-phase
Three-phase
[Us] rated mains voltage 220 test3 (- 10...15%) for three-phase
220 test3 (-20...15%) for single-phase
supply voltage limits 170...255 test3 for single-phase
200...255 test3 for three-phase
Power supply frequency 50/60 Hz (- 5...5 %)
network frequency 47,5...63 Hz
interference filter Without interference filter
Continuous output current 7 A at 16 kHz
Peak output current, 3 s 21 A at 220 test3
Continuous power 1500 test4 at 220 test3
Rated power 1.5 kW at 220 test3. 16 kHz
Switching frequency 16 kHz
Overvoltage category III
leakage current 4.5 mA
Output voltage <= напряжение питания
galvanic isolation Between the power and control circuits
cable type Shielded motor cable (temperature: 0...55 °C) copper
electrical connection Spring clamp, clamping capacity: 1.3...1.5 mm2, AWG 16 (L1-L2)
Spring clamp, clamping capacity: 1.3...1.5 mm2, AWG 16 (R, S, T)
Spring clamp, clamping capacity: 1.3...1.5 mm2, AWG 16 (U, V, W, PE)
Spring clamp, clamping capacity: 1.3...1.5 mm2, AWG 16 (PA/+, PBe)
number of digital inputs 8 Programmable (CN1)
2 quick collection (CN1)
1 safety function STO (CN9)
1 Pulse sequence input (PTI) (CN1)
digital input voltage 24 V post. Current (logical)
type of digital inputs Positive or negative (CN1)
number of digital outputs 5 logic output (CN1) at 12...24 test3 DC
1 Pulse sequence output (PTO) (CN1)
digital output voltage 12...24 test3 post. current
discrete output logic Positive or negative (CN1)
The number of the analog input 2
absolute measurement error 0.1 %
Connection type Analog voltage signal input (T_REF)
Analog voltage signal input (V_REF), - 10...10 V input impedance: 10 kOhm, resolution: 14 bits
type of control signal CN2 : servo motor encoder feedback
types of implemented protections From reverse polarity (signal at the inputs)
Short circuit protection (output signal)
Overload currents (motor)
Maximum voltage protection (motor)
Minimum voltage protection (motor)
Excess temperature (engine)
Restart (engine)
Speeding (engine)
protection function STO (Safe torque shutdown), integrated
security level SIL 2 in accordance with IEC 61800-5-2 :2007
SIL 2 in accordance with IEC 61508-1 : 2010
PL d/category 3 in accordance with EN/ISO 13849-1:2008
SIL 2 in accordance with EN/ISO 13849-1 :2009/AC
SIL 2 in accordance with EN 60204-1 : 2006
SIL 2 in accordance with EN 60204-1 : 2009/A1
SIL 2 in accordance with EN 60204-1 : 2010/AC
SIL 2 in accordance with IEC 62061 : 2012
communication interface CANmotion, integrated
CANopen, integrated
connector type RJ45 (CN4) for CANopen, CANmotion
access method The slave
transfer rate 250 kbit/s for bus length of 100...250 m for CANopen, CANmotion
500 kbit/s for bus length of 4...100 m for CANopen, CANmotion
1 Mbit/s for bus length of <= 4 m for CANopen, CANmotion
number of addresses 1...127 for CANopen, CANmotion
the physical interface RS485 (slave device serial Modbus lines)
LED status indicator 1 Red LED to check for breaks in the coil
1 LED red for charging
1 LED green for RUN
alarm function The status of the servo motor and the error code in five 7-segment.display devices
marking THIS
CSA
Asshole
type of cooling Built-in fan
working position Vertical
Product compatibility Servo motor BCH2 (130 mm, 3 motor stacks) at 1500 W
width 55 mm
height 150 mm
depth 170 mm
Product weight 1.2 kg
Output current 3 s peak value 2 21 A 220 test3
Output current 3 s peak value 3 21 A 220 test3

Operating conditions

electromagnetic compatibility The induced field (testing level:level 3, category C3) in accordance with EN/IEC 61800-3
standards EN/IEC 61800-5-1
Product certification THIS
CSA
asshole
degree of IP protection IP20
vibration resistance 3M4, amplitude=3 mm (f=9...200 test) in accordance with IEC 60721-3-3
Impact resistance 10 gn, type I according to IEC 60721-3-3
relative humidity 5...95% without condensation
Ambient operating temperature 0...55 °C
ambient temperature during storage -25...65 °C
working height <= 1000 м ( без derating )
> 1000...2000 m ( 1 % per 100 m derating )

Environmental friendliness of the offer

Compliance with environmental status A product of the Green Premium category
RoHS Directive (date format: YYWW, 2 digits of the year and 2 digits of the week number) Schneider Electric Declaration of Conformity
REACh Regulations The product does not contain particularly dangerous substances in quantities exceeding the norm.
Environmental profile of the product Disposal Guide
Instructions for disposal of the product Available