Write to
WhatsApp
Catalog

Переключатель K150H004UP

For comparison
To favorites
Vendor code:K150H004UP
-100%
Переключатель K150H004UP
Brand
Pre-order
$0$3.03
11
Delivery across Russia
On-line payment on the website
Discount system
Purchase returns
Description
Features
Reviews

Main Features

product series Harmony K
the type of device or its accessories Cam Switch Kit
name of the component K150
[Ith] conditional thermal current in the open air 150 A
installation location The front one
montage 4 holes
type of cam switch head With front panel 88 x 88 mm
handle type Black handle
locking the rotary handle with a padlock Without
representation of symbols With metallic explication, 1 - 0 - 2 black marking
cam switch function Switching contact
reverse Without
the OFF position. With the "off" position
description of the poles 4P
switching positions Left: 0° - 300°
To the right: 0° - 60°
degree of IP protection IP40 in accordance with IEC 529
IP40 according to NF C 20-010

Additional features

switching angle 60 °
[Ui] rated insulation voltage 690 V degree of contamination 3 according to EN 60947-1
690 V degree of contamination 3 in accordance with IEC 60947-1
Short circuit current 25000 A
?????? ?? ????????? ????????? 200 A through cartridge fuse, type gG
[Up] rated pulse withstand voltage 6 kV in accordance with EN 947-1
6 kV in accordance with IEC 947-1
the work of contacts Slow opening
direct opening With
electrical connection Clips with non-falling off. flexible screws-, 2 x 50 mm2
Clips with non-falling off. screws hard cable-, 2 x 70 mm2
tightening torque 2.5 N-m
switching capacity, mA 150,000 Ma post. current at 140 V 3 contacts for resistive loads (T=1 ms)
150,000 mA post. current at 24 V 1 contacts for inductive load (T=50 ms)
150000 мА пост. ток при 24 В 1 контакты для резистивные нагрузка (T=1 мс)
150,000 Ma post. current at 48 V 1 contact for resistive load (T=1 ms)
150,000 mA post. current at 48 V 2 contacts for inductive load (T=50 ms)
150,000 Ma post. current at 48 V 2 contact for resistive load (T=1 ms)
150,000 mA post. current at 70 V 3 contacts for inductive load (T=50 ms)
150,000 Ma post. current at 70 V 3 contacts for resistive load (T=1 ms)
150,000 Ma post. current at 95 V 2 contact for resistive load (T=1 ms)
50,000 mA post. current at 30 V 1 contacts for inductive load (T=50 ms)
50,000 mA post. current at 60 V 2 contacts for inductive load (T=50 ms)
50,000 mA post. current at 90 V 3 contacts for inductive load (T=50 ms)
mechanical wear resistance 300000 cycles
overall width of the CAD 88 mm
total height of the CAD 88 mm
total height of the CAD 205 mm
Product weight 0.88 kg

Operating conditions

standards EN/IEC 60947-3
certification cULus 240 V 15 hp 1 phase
cULus 240 V 25 hp 3 phases
cULus 480 V 40 hp 3 phases
cULus 120 V AC 50/60Hz 7.5 hp 1 Phase
protective design TC
Ambient operating temperature -25...55 °C
ambient temperature during storage -40...70 °C
Overvoltage category Class II according to IEC 60536
Class II according to NF C 20-030

Equipment warranty

Period The warranty period for this equipment is 18 months from the date of its commissioning, which is confirmed by the relevant document, but not more than 24 months from the date of delivery

Features
Brand
No reviews yet — yours could be the first.
All reviews 0
overall rating
Список отзывов пуст