Description
Features
Reviews
Main Features
product series | Harmony K | |
---|---|---|
the type of device or its accessories | Cam Switch Kit | |
name of the component | K150 | |
[Ith] conditional thermal current in the open air | 150 A | |
installation location | The front one | |
montage | 4 holes | |
type of cam switch head | With front panel 88 x 88 mm | |
handle type | Black handle | |
locking the rotary handle with a padlock | Without | |
representation of symbols | With metallic explication, 1 - 0 - 2 black marking | |
cam switch function | Switching contact | |
reverse | Without | |
the OFF position. | With the "off" position | |
description of the poles | 4P | |
switching positions | Left: 0° - 300° To the right: 0° - 60° |
|
degree of IP protection | IP40 in accordance with IEC 529 IP40 according to NF C 20-010 |
Additional features
switching angle | 60 ° | |
---|---|---|
[Ui] rated insulation voltage | 690 V degree of contamination 3 according to EN 60947-1 690 V degree of contamination 3 in accordance with IEC 60947-1 |
|
Short circuit current | 25000 A | |
?????? ?? ????????? ????????? | 200 A through cartridge fuse, type gG | |
[Up] rated pulse withstand voltage | 6 kV in accordance with EN 947-1 6 kV in accordance with IEC 947-1 |
|
the work of contacts | Slow opening | |
direct opening | With | |
electrical connection | Clips with non-falling off. flexible screws-, 2 x 50 mm2 Clips with non-falling off. screws hard cable-, 2 x 70 mm2 |
|
tightening torque | 2.5 N-m | |
switching capacity, mA | 150,000 Ma post. current at 140 V 3 contacts for resistive loads (T=1 ms) 150,000 mA post. current at 24 V 1 contacts for inductive load (T=50 ms) 150000 мА пост. ток при 24 В 1 контакты для резистивные нагрузка (T=1 мс) 150,000 Ma post. current at 48 V 1 contact for resistive load (T=1 ms) 150,000 mA post. current at 48 V 2 contacts for inductive load (T=50 ms) 150,000 Ma post. current at 48 V 2 contact for resistive load (T=1 ms) 150,000 mA post. current at 70 V 3 contacts for inductive load (T=50 ms) 150,000 Ma post. current at 70 V 3 contacts for resistive load (T=1 ms) 150,000 Ma post. current at 95 V 2 contact for resistive load (T=1 ms) 50,000 mA post. current at 30 V 1 contacts for inductive load (T=50 ms) 50,000 mA post. current at 60 V 2 contacts for inductive load (T=50 ms) 50,000 mA post. current at 90 V 3 contacts for inductive load (T=50 ms) |
|
mechanical wear resistance | 300000 cycles | |
overall width of the CAD | 88 mm | |
total height of the CAD | 88 mm | |
total height of the CAD | 205 mm | |
Product weight | 0.88 kg |
Operating conditions
standards | EN/IEC 60947-3 | |
---|---|---|
certification | cULus 240 V 15 hp 1 phase cULus 240 V 25 hp 3 phases cULus 480 V 40 hp 3 phases cULus 120 V AC 50/60Hz 7.5 hp 1 Phase |
|
protective design | TC | |
Ambient operating temperature | -25...55 °C | |
ambient temperature during storage | -40...70 °C | |
Overvoltage category | Class II according to IEC 60536 Class II according to NF C 20-030 |
Equipment warranty
Period | The warranty period for this equipment is 18 months from the date of its commissioning, which is confirmed by the relevant document, but not more than 24 months from the date of delivery |
---|
Features
Brand
Schneider
No reviews yet — yours could be the first.
All reviews 0