AGAM -two-stage indirect safety valves of the type with a balanced shut-off element are designed for operation in hydraulic systems.
In the standard version, the pressure controlling the shut-off element 1 of the main stage 2 is regulated using a screw closed with a protective cap 3 in the housing 4. On request, a version is available in which the pressure setting is changed using a screw with a handle 5 instead of a turnkey screw with a protective cap.
The AGAM type valve can be equipped with a discharge solenoid valve 6 (for normally open or normally closed valves).
They are also available with an additional safety option - a sealed regulator: The valves are adjusted in production to the flow required by the buyer.
The AGAM can be equipped with an electrically controlled valve for purging or for setting different pressure levels.
Mounting surface: ISO 6264 dimensions 10, 20 and 32
Maximum flow rate: 200, 400, and 600 l/min, respectively
Maximum pressure: up to 350 atm.
Max. flow rate l/min 200
Pressure range 8-350