Series of converters VLT Lift Drive LD 302 productions Danfoss designed to ensure the safe and comfortable operation of elevator equipment (with traction pulley, hydraulic). The most practical design, the installation of this drive will take no more than 10 minutes. Asynchronous and synchronous (permanent magnet) motors are controlled with an open and closed circuit.
Intelligent capabilities allow you to reduce noise to a minimum, adjust the optimal cooling mode and save energy resources. Reliability of operation in harsh conditions is also ensured by a special coating of sensitive elements, boards. The rigidity of the structure ensures stable operation when exposed to vibration factors.
The model range is presented in one power rating, twelve dimensions are available in the range of small and medium capacities. Optionally, the housing can be completely protected from dust and water.
Applications: passenger elevators in medium and high-rise buildings, freight elevators, specialized lifts (ski, boat, etc.), shaft elevators, escalators, etc.
Technical characteristics of Danfoss VLT Lift Drive LD 302 electric drives
- Supply voltage: 3AC 380 - 480 V;
- Electric motor power: 4 - 55 kW;
- Output current: 10 - 106 A;
- Management methods: scalar, vector (touch and sensorless);
- Output frequency: 0 - 590 Hz;
- Permissible overloads: the normal mode is up to 110% of the nom. current for 60 seconds, heavy duty - up to 160% of nom. current for 60 seconds;
- Enclosure protection class: IP20 (on request IP55, IP66);
- Interfaces: RS485, USB, DCP 3/43, CANopen;
- Visualization and customization tools: control panel with LCD display, push-button navigation, software for control and parameterization using a personal computer;
- Other features and functions: automatic diagnostics, profile settings, safe torque removal, controlled mechanical and dynamic braking and others.
VLT Lift Drive LD 302 I/O Configuration
- Analog: 2 inputs and 1 output;
- Digital: 4 inputs and 2 outputs;
- relay: 2 exits.
- connection of feedback sensors.
Optional VLT Lift Drive LD 302 Drive Modules
- I/O expansion cards.
- Filters to improve anti-interference protection.
- External power supply for fault protection (24 V DC).
Parameters of standard sizes of electric drives VLT Lift Drive LD 302
Type of drive | Current, A | Motor power, kW | ||
norm. mode | heavy. mode | norm. mode | heavy. mode | |
LD-302P4K0T4… | - | 10 | - | 4,0 |
LD-302P5K5T4… | - | 13 | - | 5,5 |
LD-302P7K5T4… | - | 16 | - | 7,5 |
LD-302P11KT4… | 32 | 24 | 15 | 11 |
LD-302P15KT4… | 37,5 | 32 | 18,5 | 15 |
LD-302P18KT4… | 44 | 37,5 | 22 | 18,5 |
LD-302P22KT4… | 61 | 44 | 30 | 22 |
LD-302P30KT4… | 73 | 61 | 37 | 30 |
LD-302P55KT4… | 147 | 106 | 75 | 55 |
You can buy Danfoss VLT Lift Drive LD 302 frequency converters, find out the price and more information about the products by contacting our specialists.