Microprocessor-based DC electric drive Sinamics DC Master - the company's new solution Siemens for regulation and control of technological applications in the field of direct current (electric motors, power supplies, rectifiers).
Built on the basis of the Sinamics platform, which is unified for modern Siemens drives, the Sinamics DCM electric drive combines the advantages of the predecessor Simoreg DC Master and advanced Motion Control technologies from Siemens.
The use of Motion Control technologies has made it possible to create a modern cost-effective solution that allows, if necessary, to increase the functionality of the system through additional modules and software. (Example: the Simoreg DC Master 6RA70 drive in the basic configuration already included a large number of functionality, all this was included in the cost of the equipment, but at the same time the user used no more than 50% of its capabilities).
At the moment, our organization is making a gradual transition to using the modern generation of Siemens thyristor electric drives.
Rated characteristics of digital direct current drives Sinamics DC Master
The input voltage of the electric drive is 3x400V ±10% 50Hz
Name of the drive | Drive Parameters | |||
irreversible | reversible | Ia, And | Iexc, And | Pn, kW |
- | 6RA8013-6DV62-0AA0 | 15 | 3 | 6,3 |
- | 6RA8018-6DV62-0AA0 | 30 | 5 | 14,5 /12,6 |
6RA8025-6DS22-0AA0 | 6RA8025-6DV62-0AA0 | 60 | 10 | 29 /25,2 |
6RA8028-6DS22-0AA0 | 6RA8028-6DV62-0AA0 | 90 | 10 | 44 /37,8 |
6RA8031-6DS22-0AA0 | 6RA8031-6DV62-0AA0 | 125 | 10 | 61 /52,5 |
6RA8075-6DS22-0AA0 | 6RA8075-6DV62-0AA0 | 210 | 15 | 102 /88,8 |
6RA8078-6DS22-0AA0 | 6RA8078-6DV62-0AA0 | 280 | 15 | 136 /118 |
6RA8081-6DS22-0AA0 | 6RA8081-6DV62-0AA0 | 400 | 25 | 194 /168 |
6RA8085-6DS22-0AA0 | 6RA8085-6DV62-0AA0 | 600 | 25 | 291 /252 |
6RA8087-6DS22-0AA0 | 6RA8087-6DV62-0AA0 | 850 | 30 | 412 /357 |
6RA8091-6DS22-0AA0 | 6RA8091-6DV62-0AA0 | 1200 | 40 | 582 /504 |
6RA8093-4DS22-0AA0 | 6RA8093-4DV62-0AA0 | 1600 | 40 | 776 /672 |
6RA8095-4DS22-0AA0 | 6RA8095-4DV62-0AA0 | 2000 | 40 | 970 /840 |
6RA8098-4DS22-0AA0 | 6RA8098-4DV62-0AA0 | 3000 | 40 | 1455 /1260 |
Ua=485V (for non-reversible drive), Ua=420V (for reversible drive), Uexc=325V (for drives up to 850A) Uexc=375V (for drives from 1200A)
Rated characteristics of digital direct current drives Sinamics DC Master
The input voltage of the electric drive is 3x480V ±10% 50HzName of the drive | Drive Parameters | |||
irreversible | reversible | Ia, And | Iexc, And | Pn, kW |
- | 6RA8013-6FV62-0AA0 | 15 | 3 | 6,3 |
- | 6RA8018-6FV62-0AA0 | 30 | 5 | 16,5 /15 |
6RA8025-6FS22-0AA0 | 6RA8025-6FV62-0AA0 | 60 | 10 | 34,5 /30 |
6RA8028-6FS22-0AA0 | 6RA8028-6FV62-0AA0 | 90 | 10 | 51,8 /45 |
6RA8031-6FS22-0AA0 | 6RA8031-6FV62-0AA0 | 125 | 10 | 71,9 /62,5 |
6RA8075-6FS22-0AA0 | 6RA8075-6FV62-0AA0 | 210 | 15 | 121 /105 |
6RA8078-6FS22-0AA0 | 6RA8078-6FV62-0AA0 | 280 | 15 | 161 /140 |
6RA8082-6FS22-0AA0 | 6RA8082-6FV62-0AA0 | 450 | 25 | 259 /225 |
6RA8085-6FS22-0AA0 | 6RA8085-6FV62-0AA0 | 600 | 25 | 345 /300 |
6RA8087-6FS22-0AA0 | 6RA8087-6FV62-0AA0 | 850 | 30 | 489 /425 |
6RA8091-6FS22-0AA0 | 6RA8091-6FV62-0AA0 | 1200 | 40 | 690 /600 |
Ua=575V (for non-reversible drive), Ua=500V (for reversible drive), Uexc=375V
Rated characteristics of Sinamics DCM DC digital electric drives
The input voltage of the electric drive is 3x575V ±10% 50Hz
Name of the drive | Drive Parameters | |||
irreversible | reversible | Ia, And | Iexc, And | Pn, kW |
6RA8025-6GS22-0AA0 | 6RA8025-6GV62-0AA0 | 60 | 10 | 41,4 /35 |
6RA8031-6GS22-0AA0 | 6RA8031-6GV62-0AA0 | 125 | 10 | 86,3 /75 |
6RA8075-6GS22-0AA0 | 6RA8075-6GV62-0AA0 | 210 | 15 | 145 /126 |
6RA8081-6GS22-0AA0 | 6RA8081-6GV62-0AA0 | 400 | 25 | 276 /240 |
6RA8085-6GS22-0AA0 | 6RA8085-6GV62-0AA0 | 600 | 25 | 414 /360 |
6RA8087-6GS22-0AA0 | 6RA8087-6GV62-0AA0 | 800 | 30 | 552 /510 |
6RA8090-6GS22-0AA0 | 6RA8090-6GV62-0AA0 | 1100 | 40 | 759 /660 |
6RA8093-4GS22-0AA0 | 6RA8093-4GV62-0AA0 | 1600 | 40 | 1104 /960 |
6RA8095-4GS22-0AA0 | 6RA8095-4GV62-0AA0 | 2000 | 40 | 1380 /1200 |
6RA8096-4GS22-0AA0 | 6RA8096-4GV62-0AA0 | 2200 | 40 | 1518 /1320 |
6RA8097-4GS22-0AA0 | 6RA8097-4GV62-0AA0 | 2800 | 40 | 1932 /1680 |
Ua=690V (for non-reversible drive), Ua=600V (for reversible drive), Uexc=375V
Rated characteristics of Sinamics DCM DC digital electric drives
The input voltage of the electric drive is 3x690V ±10% 50Hz
Name of the drive | Drive Parameters | |||
irreversible | reversible | Ia, And | Iexc, And | Pn, kW |
6RA8086-6KS22-0AA0 | 6RA8086-6KV62-0AA0 | 720 /760 | 30 | 598 /551 |
6RA8090-6KS22-0AA0 | 6RA8090-6KV62-0AA0 | 1000 | 40 | 830 /725 |
6RA8093-4KS22-0AA0 | 6RA8093-4KV62-0AA0 | 1500 | 40 | 1245 /1088 |
6RA8095-4KS22-0AA0 | 6RA8095-4KV62-0AA0 | 2000 | 40 | 1660 /1450 |
6RA8097-4KS22-0AA0 | 6RA8097-4KV62-0AA0 | 2600 | 40 | 2158 /1885 |
Ua=830V (for non-reversible drive), Ua=725V (for reversible drive), Uexc=375V
Uin is the input voltage, Ia is the armature current, Ua is the armature voltage, Iexc is the excitation current, Uexc is the excitation voltage, Pn is the rated power.