Description
Features
Reviews
PL – 2 is a quadrant, non-reversible Sprint Electric DC electric drive, most models have a built-in controlled regenerative braking device, which allows you to completely abandon expensive brake resistors or even the use of 4 quadrant drives.
PLX – 4 is a quadrant, reversible Sprint Electric DC electric drive with the ability to recover energy and control DC motors with rotation and braking in both directions.
Rated output power and current: BKD6: 5 - 980 kW, 12 – 2250 A;
Excitation current – from 8 to 64 A (depending on the model);
Supply voltage ratings:
- Power 3-phase 50 – 60 Hz: any voltage from 12 to 480 VAC ± 10% to supply the armature winding;
- Auxiliary 3-phase 50 – 60 Hz: any voltage from 100 to 480 VAC ± 10% to supply the field winding;
- Control 1-phase 50 – 60 Hz: any voltage from 110 to 240 VAC ± 10%, 50 VA;
Overload capacity: 150% 25 seconds;
Motor speed control modes
- by feedback from the winding voltage (AVF) with IR member compensation;
- by feedback from the encoder or analog tachogenerator;
- by combined feedback from the encoder and analog tachogenerator or AVF;
The typical control range is 1:100 with feedback from the tachogenerator.
Accuracy of control of the electric motor in steady-state mode
- 0.1% with feedback from an analog tachogenerator (depends on the tachogenerator);
- 2% with armature voltage feedback;
- 0.01% encoder only, encoder + tachogenerator, encoder + AVF – (with digital assignment);
Design features of Sprint Electric direct current drives of the PL/PLX series
- easy parameterization of the drive using the built-in display and menu buttons;
- RS-232 interface - for parameterization and diagnostics using the free PL PILOT software;
- Tachogenerator input - ± 200 VDC. current and incremental encoder;
- field attenuation, motorized potentiometer simulator, connection conflict check, dual motor switching, spindle orientation, 3 pages of settings sets, configuration utility and
PC control, a family of remote interface units;
- built-in motor thermistor input;
- the possibility of embedding three-phase network reactors.
Configuration of inputs/outputs of electric drives PL /PLX
- 8 analog inputs with a resolution of up to 5 mV plus a sign (+/- 0.4%), 4 input voltage ranges ±5/10/20/30 V at each input;
- 4 analog outputs ±10 V (3 programmable, 1 fixed, for the actual armature current);
- 4 digital programmable inputs +24 V;
- 4 digital programmable outputs capable of controlling 24 V relays, indicators, sensors, etc.;
- 1 internal contactor control relay;
Optional PL/PLX electric drive modules
Parameterization and display modules: A remotely installed display unit, 300 pages of menus and submenus. Each page can show up to 8 parameters, including numeric, text, and bitwise;
Modules of industrial communication protocols: Profibus, DeviceNet.
PLX – 4 is a quadrant, reversible Sprint Electric DC electric drive with the ability to recover energy and control DC motors with rotation and braking in both directions.
Technical characteristics of Sprint-Electric PL /PLX electric drives
Rated output power and current: BKD6: 5 - 980 kW, 12 – 2250 A;
Excitation current – from 8 to 64 A (depending on the model);
Supply voltage ratings:
- Power 3-phase 50 – 60 Hz: any voltage from 12 to 480 VAC ± 10% to supply the armature winding;
- Auxiliary 3-phase 50 – 60 Hz: any voltage from 100 to 480 VAC ± 10% to supply the field winding;
- Control 1-phase 50 – 60 Hz: any voltage from 110 to 240 VAC ± 10%, 50 VA;
Overload capacity: 150% 25 seconds;
Motor speed control modes
- by feedback from the winding voltage (AVF) with IR member compensation;
- by feedback from the encoder or analog tachogenerator;
- by combined feedback from the encoder and analog tachogenerator or AVF;
The typical control range is 1:100 with feedback from the tachogenerator.
Accuracy of control of the electric motor in steady-state mode
- 0.1% with feedback from an analog tachogenerator (depends on the tachogenerator);
- 2% with armature voltage feedback;
- 0.01% encoder only, encoder + tachogenerator, encoder + AVF – (with digital assignment);
Design features of Sprint Electric direct current drives of the PL/PLX series
- easy parameterization of the drive using the built-in display and menu buttons;
- RS-232 interface - for parameterization and diagnostics using the free PL PILOT software;
- Tachogenerator input - ± 200 VDC. current and incremental encoder;
- field attenuation, motorized potentiometer simulator, connection conflict check, dual motor switching, spindle orientation, 3 pages of settings sets, configuration utility and
PC control, a family of remote interface units;
- built-in motor thermistor input;
- the possibility of embedding three-phase network reactors.
Configuration of inputs/outputs of electric drives PL /PLX
- 8 analog inputs with a resolution of up to 5 mV plus a sign (+/- 0.4%), 4 input voltage ranges ±5/10/20/30 V at each input;
- 4 analog outputs ±10 V (3 programmable, 1 fixed, for the actual armature current);
- 4 digital programmable inputs +24 V;
- 4 digital programmable outputs capable of controlling 24 V relays, indicators, sensors, etc.;
- 1 internal contactor control relay;
Optional PL/PLX electric drive modules
Parameterization and display modules: A remotely installed display unit, 300 pages of menus and submenus. Each page can show up to 8 parameters, including numeric, text, and bitwise;
Modules of industrial communication protocols: Profibus, DeviceNet.
Nominal characteristics of standard sizes of Sprint-Electric PL /PLX digital drives
Drive model | Power, at 415 V ACW | Output current, A | Excitation current, A | Overall dimensions x H x hmmm |
PL /PLX 5 | 5 | 12 | 8 | 289 x 216 x 174 |
PL /PLX 10 | 10 | 24 | ||
PL /PLX 15 | 15 | 36 | ||
PL /PLX 20 | 20 | 51 | ||
PL /PLX 30 | 30 | 72 | ||
PL /PLX 40 | 40 | 99 | ||
PL /PLX 50 | 50 | 123 | ||
PL /PLX 65 | 65 | 155 | 16 | 410 x 216 x 218 |
PL /PLX 85 | 85 | 205 | ||
PL /PLX 115 | 115 | 270 | ||
PL /PLX 145 | 145 | 330 | ||
PL /PLX 185 | 185 | 430 | 32 (or 50 on request) | 505 x 216 x 294 |
PL /PLX 225 | 225 | 530 | ||
PL /PLX 265 | 265 | 630 | ||
PL /PLX 275 | 275 | 650 | 32(or 50 on request) | 700 x 253 x 350 |
PL /PLX 315 | 315 | 750 | ||
PL /PLX 360 | 360 | 850 | ||
PL /PLX 400 | 400 | 950 | ||
PL /PLX 440 | 440 | 1050 | ||
PL /PLX 520 | 520 | 1250 | 64 | 700 x 506 x 350 |
PL /PLX 600 | 600 | 1450 | ||
PL /PLX 700 | 700 | 1650 | ||
PL /PLX 800 | 800 | 1850 | ||
PL /PLX 900 | 900 | 2050 | ||
PL /PLX 980 | 980 | 2250 |
Features
Power, kW:
85
Rated current, A
205
Brand
Sprint Electric
No reviews yet — yours could be the first.