Features
Reviews

Main Features

range TeSys
Product name TeSys D
the type of device or its accessories Contactor
short name of the device LC1D
contactor application Electric motor control
Active load
Application category AC-1
AC-3
AC-4
description of the poles 3P
configuration of the main contacts 3 N.O.
[Ue] rated operating voltage <= 300 В постоянный ток для силовая цепь
<= 1000 V переменный ток 25...400 Hz для силовая цепь
[Icw] rated short-term permissible current 200 A (<= 60 °C) в <= 440 V переменный ток AC-1 для силовая цепь
115 A (<= 60 °C) в <= 440 V переменный ток AC-3 для силовая цепь
engine power, kW 55 kW in 380...400 V alternating current 50/60 Hz AC-3
75 kW 500 V AC 50/60 Hz AC-3
80 kW in 660...690 V AC 50/60 Hz AC-3
30 kW 220...230 V alternating current 50/60 Hz AC-3
59 kW at 415...440 V AC 50/60 Hz AC-3
65 kW 1000 V AC 50/60 Hz AC-3
18.5kW 400 V AC 50/60 Hz AC-4
engine power, hp 30 HP 200/208 V Alternating current 50/60 Hz for 3 Phase electric motors
40 HP 230/240 V Alternating current 50/60 Hz for 3 Phase electric motors
75 HP V 460/480 V Alternating current 50/60 Hz for 3 Phase electric motors
100 hp 575/600 V AC 50/60 Hz for 3 Phase Electric motors
type of control circuit Post. The current is standard
control circuit voltage 110 V post. current
vspom. contacts available on each contactor 1 N.O. + 1 N.Z.
[Up] rated pulse withstand voltage In accordance with IEC 60947
Overvoltage category III
[Ith] conditional thermal current in the open air 200 A V <= 60 °C для силовая цепь
Rated switching capacity of Irms 1260 A to 440 V for power circuit according to IEC 60947
140 A alternating current for alarm circuit according to IEC 60947-5-1
250 A direct current for alarm circuit according to IEC 60947-5-1
rated breaking capacity 1100 A to 440 V for power circuit according to IEC 60947
[Icw] rated short-term sustained current 1100 A <= 40 °C 1 с силовая цепь
100 A 1 s alarm circuit
120 A 500 ms alarm circuit
140 A 100 ms alarm circuit
250 A <= 40 °C 10 мин силовая цепь
550 A <= 40 °C 1 мин силовая цепь
950 A <= 40 °C 10 с силовая цепь
the corresponding fuse rating 200 A gG in <= 690 V координация тип 2 для силовая цепь
250 A gG in <= 690 V координация тип 1 для силовая цепь
10 A gG for alarm circuit
average total resistance 0.6mOhm V 50 Hz - Ith 200 A for power circuit
[Ui] rated insulation voltage 1000 V for power circuit according to IEC 60947-4-1
600 V for CSA certification power circuit
600 V for UL certification power circuit
690 V for alarm circuit according to IEC 60947-1
600 V for CSA certification alarm circuit
600 V for UL certification alarm circuit
electrical wear resistance 0.8 million cycles of 200 A AC-1 at Ue <= 440 V
0.95 million cycles 115 A AC-3 at Ue <= 440 V
power dissipated by one pole 24W AC-1
7.9W AC-3
protective cover With
mounting support Panel mounting
The rail
standards CSA C22.2 № 14
EN 60947-4-1
EN 60947-5-1
IEC 60947-4-1
IEC 60947-5-1
UL 508
Product certification BV
CCC
CSA
DNV
GL
GOST
LROS (Lloyds register of shipping)
RINA
UL
accessions Control circuit : screw clamp 2 cable(s) 1...2.5 mm2 - cable stiffness: flexible - without cable tip
Control circuit : screw clamp 2 cable(s) 1...2.5 mm2 - cable stiffness: flexible - with cable tip
Control circuit : screw clamp 2 cable(s) 1...2.5 mm2 - cable stiffness: rigid cable - without cable tip
Control circuit : screw clamp 1 cable(s) 1...2.5 mm2 - cable stiffness: flexible - with cable tip
Control circuit : screw clamp 1 cable(s) 1...2.5 mm2 - cable stiffness: flexible - without cable tip
Control circuit : screw clamp 1 cable(s) 1...2.5 mm2 - cable stiffness: rigid cable - without cable tip
Power circuit : connector 1 cable(s) 10...120 mm2 - cable stiffness: flexible - without cable tip
Power circuit : Connector 2 cable(s) 10...50 mm2 - cable stiffness: flexible - without cable tip
Power circuit : connector 1 cable(s) 10...120 mm2 - cable stiffness: flexible - with cable tip
Power circuit : Connector 2 cable(s) 10...50 mm2 - Cable stiffness: flexible - with cable tip
Power circuit : connector 1 cable(s) 10...120 mm2 - cable stiffness: rigid cable - without cable tip
Power circuit : Connector 2 cable(s) 10...50 mm2 - cable stiffness: rigid cable - without cable tip
tightening torque Control circuit : 1.2 N-m - screw clamp - flat with a screwdriver. Ø 6 mm
Control circuit : 1.2 N-m - screw clamp - using a Philips No. 2 screwdriver
Power circuit : 12 N-M - 4 mm hex socket
Response time 20...35 ms switching on
40...75 ms shutdown
a safe level of reliability B10d=1369863 cycles contactor with rated load according to EN/ISO 13849-1
B10d=20000000 cycles contactor with mechanical load according to EN/ISO 13849-1
mechanical wear resistance 8 million cycles
Operating frequency 1200 cycle/h in <= 60 °C

Additional features

the technology of using coils With built-in interference suppression device
voltage limits of the control circuit 0.75...1.2 Uc is in operation at 55 °C, direct current
0.15...0.4 Uc release at 55 °C, direct current
the time constant 25 ms
starting power, W 270...365 Watts at 20 °C
power consumption when holding, W 2.4...5.1 W at 20 °C
the type of vspom. contacts Type mechanically coupled (1 N.O. + 1 N.Z.) in accordance with IEC 60947-5-1
Type duplicate contact (1 N.Z.) in accordance with IEC 60947-4-1
alarm circuit frequency 25...400 Hz
minimum switching current 5 mA for alarm circuit
minimum switching voltage 17 V for alarm circuit
time without overlap 1.5 ms when voltage is removed (between NC and NO contact)
1.5 ms when voltage is applied (between NC and NO contact)
insulation resistance > 10 mOhm for alarm circuit

Operating conditions

degree of IP protection IP20 front panel in accordance with IEC 60529
protective design TH in accordance with IEC 60068-2-30
degree of contamination 3
Ambient operating temperature -5...60 °C
ambient temperature during storage -60...80 °C
permissible air temperature around the device -40...70 °C at Uc
working height 3000 m without temperature degradation
Fire resistance 850 °C in accordance with IEC 60695-2-1
Fire resistance V1 in accordance with UL 94
mechanical resistance Vibration contactor is open 2 g (nom.), 5...300 Hz
Vibration contactor is closed 4 g (nom.), 5...300 Hz
Shocks The contactor is closed 15 g (nom.) for 11 ms
Shocks The contactor is open 6 g (nom.) for 11 ms
height 158 mm
width 120 mm
depth 136 mm
Product weight 2.5 kg

Features
Brand
No reviews yet — yours could be the first.
All reviews 0
overall rating
Список отзывов пуст