Description
Features
Reviews
Main Features
range | TeSys | |
---|---|---|
Product name | TeSys D | |
the type of device or its accessories | The star-triangle starter | |
short name of the device | LC3D | |
contactor application | Electric motor control | |
Application category | AC-3 | |
Product configuration | With completed electrical installation | |
description of the poles | 3x 3P | |
the composition of the pole contacts | 3x 3 N.O. | |
[Ue] rated operating voltage | <= 690 V переменный ток 25...400 Hz для силовая цепь | |
[Icw] rated short-term permissible current | 32 A (<= 60 °C) переменный ток AC-3 для силовая цепь в <= 440 V | |
engine power, kW | 15 kw 220/230 V AC 50/60 Hz 25 kw 380/400 V AC 50/60 Hz 30 kW 415 V AC 50/60 Hz 30 kW 440 V AC 50/60 Hz |
|
type of control circuit | Per. Current 50/60 Hz | |
control circuit voltage | 230 V Alternating current 50/60 Hz | |
vspom. contacts available on each contactor | 1 N.Z. for KM1 star contactor | |
[Up] rated pulse withstand voltage | 6 kV in accordance with IEC 60947 | |
Overvoltage category | III | |
[Ui] rated insulation voltage | 690 test3 according to IEC 60947-4-1 power circuit 600 V CSA certified power circuit 600 V UL certified power circuit 690 test3 according to IEC 60947-1 alarm circuit 600 V CSA certification alarm circuit 600 V UL certification alarm circuit |
|
electrical wear resistance | 1.65 million cycles of 32 A AC-3 <= 440 V | |
supplied equipment | Protective coating | |
type of blocking | Mechanical | |
mounting support | Panel mounting | |
standards | EN 60947-4-1 EN 60947-5-1 IEC 60947-4-1 IEC 60947-5-1 UL 508 CSA C22.2 № 14 |
|
Product certification | BV CCC CSA DNV GL GOST LROS (Lloyds register of shipping) RINA UL |
Additional features
accessions | Screw clamp for control circuit 1 1...4 mm2 flexible without tip Screw clamp for control circuit 2 1...4 mm2 flexible without tip Screw clamp for control circuit 1 1...4 mm2 Flexible with cable tip Screw clamp for control circuit 2 1...2.5 mm2 Flexible with cable tip Screw clamp for control circuit 1 1...4 mm2 hard cable without tip Screw clamp for control circuit 2 1...4 mm2 hard cable without tip Screw clamp for power chain 1 2.5...10 mm2 Flexible without tip Screw clamp for power circuit 2 2.5...10 mm2 Flexible without tip Screw clamp for Power circuit 1 1...10 mm2 Flexible with Cable tip Screw clamp for Power circuit 2 1.5...6 mm2 Flexible with Cable Tip Screw clamp for power circuit 1 1.5...10 mm2 hard cable without tip Screw clamp for power circuit 2 2.5...10 mm2 hard cable without tip |
|
---|---|---|
tightening torque | 1.7 N-m for the control circuit, the screw clamp is flat. Ø 6 mm 1.7 N-m for Philips Screw Clamp control circuit No 2 2.5 N-m for the power circuit, the screw clamp is flat. Ø 6 mm 2.5N-m for Power Circuit Screw Clamp Philips No 2 |
|
mechanical wear resistance | 15 million cycles | |
Operating frequency | 30 cycle/h at <= 60 °C | |
start-up duration | 30 s | |
the technology of using coils | Without built-in overload protection module | |
voltage limits of the control circuit | 0.3...0.6 Uc at 60 °C release 50/60 Hz 0.8...1.1 Uc at 60 °C is in the operating state of 50 Hz 0.85...1.1 Uc at 60 °C is in the 60 Hz operating state |
|
power consumption when triggered | 70 VA at 20 °C 0.75 60 Hz 70 VA at 20 °C 0.75 50 Hz |
|
power consumption during holding, V·A | 7.5 VA at 20 °C 0.3 60 Hz 7 VA at 20 °C 0.3 50 Hz |
|
heat transfer | 2...3 Watts at 50/60 Hz | |
the type of vspom. contacts | Mechanically bonded in accordance with IEC 60947-5-1 3x 1 N.O. + 1 N.Z. Duplicate contact in accordance with IEC 60947-4-1 3x 1 N.Z. |
|
alarm circuit frequency | 25...400 Hz | |
minimum switching current | 5 mA for alarm circuit | |
switching voltage | 17 V for alarm circuit | |
time without overlap | 1.5 ms when the voltage is applied between the NC and NO contact 1.5 ms when the voltage is removed between the NC and NO contact |
|
width | 166 mm | |
height | 124 mm | |
depth | 149 mm | |
Product weight | 2.03 kg |
Operating conditions
insulation resistance | > 10 mOhm for alarm circuit | |
---|---|---|
degree of IP protection | IP20 front panel in accordance with IEC 60529 | |
protective design | TH in accordance with IEC 60068-2-30 | |
degree of contamination | 3 | |
ambient temperature during storage | -60...80 °C | |
Ambient operating temperature | -40...70 °C at Uc | |
working height | 3000 m without temperature degradation | |
Fire resistance | 850 °C in accordance with IEC 60695-2-1 | |
Fire resistance | V1 in accordance with UL 94 | |
mechanical resistance | Vibration contactor is open 2 g (nom.), 5...300 Hz Vibration contactor is closed 4 g (nom.), 5...300 Hz Shocks The contactor is closed 15 g (nom.) for 11 ms Shocks The contactor is open 8 g (nom.) for 11 ms |
Features
Brand
Schneider
No reviews yet — yours could be the first.
All reviews 0
Список отзывов пуст