Write to
WhatsApp
Write to
Telegram
Catalog

Capacitive collector FMI52-V2BDRJA2A3A

For comparison
To favorites
Vendor code:FMI52-V2BDRJA2A3A
Capacitive collector FMI52-V2BDRJA2A3A
Power Supply, In
Brand
Pre-order
$1 639,65
11
Delivery across Russia
On-line payment on the website
Discount system
Purchase returns
Description
Features
Reviews

Liquicap FMI52 It is a reliable device with a fully insulated cable probe designed for continuous measurement of liquid levels, especially in small tanks, for environments prone to sediment formation and heated to extremely high temperatures (especially for large measuring ranges). These measurements do not depend on the value of the dielectric constant. When used in conjunction with the Fieldgate FXA320 device (remote transmission of measurement data using Internet technologies), Liquicap it is an ideal solution for accounting systems.

Specifications:

Principle of measurement The intensity principle of measurement characteristics/Fully insulated rod probe, suitable for both typical and extreme applications (temperature, pressure)
Measurement of the interface level Phase measurement of the interfacial level even in the presence of an emulsion layer
Additional InformationThe presence of the inactive part of the probe
Factory calibration
high performance
Food /Communication 12-36V DC HART
PFM

Repeatability error 0.1%
Linear error for conductive liquids<0,25%
The ambient temperature is 50°C...+70°C
The operating temperature is 80°C...200°C
Working pressure abs. /max. overpressure limit Vacuum ... 100 bar
Wetted parts Insulation material: FEP,PFA
316L
Process connection G 3/4, G 1, G1 1/2 /NPT 3/4", NPT 1, NPT1 1/2"
Flanged connections from DN25.../ANSI 1".../JIS...
Hygienic connection to the PROCESSGI-Clamp ISO02852
Milk Nut
Flush connection

Sensor length Total length: 6m
Inactive length: max. 2m
Max. The measurement value is 0.42 m ... 10.0 m
Exit 4...20mA HART
CHIM
Certificates/Technical standards
TIIS
NEPSI
WHG
SIL
EHEDG
marine GL
Safety approvalsOverfill prevention WHG
SIL


Construction Certificate EN 10204-3.1
NACE MR0175

Hygiene certificationsehedg

Marine Certificate GL/ABS

Optional case design
gas-tight seal

The range of application is the changing physical properties of the medium, the conductivity of the medium < 100 мкСм/см

Exceeding the permissible values of temperature and pressure